D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.
Empty and material horsepower
HPf = Fd Fb L N / 10⁶ | HPm = ṁ Fm L / 10⁶
The KWS control-fed convention uses L in feet, ṁ in lb/h and empirical diameter, hanger and material factors. Diameter factor is interpolated through the published screw diameters. The optional multiplier applies to material power. Obtain OEM correction for low material HP, startup and flood feeding.
Gravity, motor and shaft torque
Plift = ṁ g L sin α | Pshaft = Pf + multiplier · Pm + Plift
Pmotor = Pshaft/η | τ = Pshaft/(2πN/60)
Use kg/s for ṁ and watts for the SI torque equation. Torque is at the screw shaft, after the drive losses used to estimate motor size.
Compared with the same screw operating horizontally.
Inputs
Screw OD
16 in
Pipe shaft OD
4 in
Flight pitch
16 in
Trough loading
45%
Screw speed
52 RPM
Incline angle
0°
Conveyor length
36 ft
Bulk density
64 lb/ft³
Incline capacity retained
0%
Material factor Fm
1.35
Hanger bearing factor
2
Material power multiplier
1
Drive efficiency
88%
Calculated values
Volume throughput
2,450.442CFH
Mass throughput
78.414TPH
Screw shaft torque
9,718.898lb-in
Motor power
9.112HP
Open flight annulus
1.309ft²
Incline capacity retained
100%
Effective fill after derate
45%
Diameter factor
106
Empty screw power
0.397HP
Material power before multiplier
7.622HP
Vertical rise
0ft
Gravity lift power
0HP
Screw shaft power
8.019HP
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.