Worked example · Screw Conveyor

24-inch slow heavy-duty auger

A heavily loaded, large-diameter auger uses a slow final shaft speed. The material has an elevated drag factor.

Live results

Auger flight, pitch and loaded annulus

Edit inputs
Auger flight, pitch and loaded annulus Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. VOLUME RATE2290.22CFHMASS RATE131.69TPHSHAFT TORQUE1.5e+5lb-inMOTOR POWER81.01HP AUGER FLIGHTTROUGH SECTIONFlowPitch 18 in8° inclineFlight OD 24 in28.8% effective fill Incline capacity retained96%Compared with the same screw operating horizontally.

Compared with the same screw operating horizontally.

All calculated values
Volume throughput
2,290.221CFH
Mass throughput
131.688TPH
Screw shaft torque
149,763.269lb-in
Motor power
81.008HP
Open flight annulus
2.945ft²
Incline capacity retained
96%
Effective fill after derate
28.8%
Diameter factor
235
Empty screw power
0.691HP
Material power before multiplier
46.459HP
Vertical rise
6.819ft
Gravity lift power
0.907HP
Screw shaft power
71.287HP

Inputs

Unit system
Operating inputs
in
in
in
RPM
°
ft
lb/ft³
Drive & model factors
%
0 applies the angle-based estimate. Enter a measured percentage to override it.
Enter an OEM overload or fallback allowance if known.
%

Worked solution

Starting case in US units

  1. Subtract the 6 in shaft from the 24 in flight envelope to get an open area of 2.95 ft².
  2. With 18 in pitch, 30 RPM, 30% loading and 96% retained capacity, the auger moves 2290.22 CFH or 131.69 TPH.
  3. Add empty, corrected material and gravity power. The screw shaft uses 71.29 HP and 1.5e+5 lb-in at the entered speed.

Try it. Use the calculated shaft power and shaft speed together when comparing torque with equipment ratings.

More worked examples

Open a different starting case

Equations and assumptions

Annular displacement and incline

Qᵥ = (π/4)(D² − d²) · p · N · 60 · f · k

D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.

Empty and material horsepower

HPf = Fd Fb L N / 10⁶   |   HPm = ṁ Fm L / 10⁶

The KWS control-fed convention uses L in feet, ṁ in lb/h and empirical diameter, hanger and material factors. Diameter factor is interpolated through the published screw diameters. The optional multiplier applies to material power. Obtain OEM correction for low material HP, startup and flood feeding.

Gravity, motor and shaft torque

Plift = ṁ g L sin α   |   Pshaft = Pf + multiplier · Pm + Plift
Pmotor = Pshaft/η   |   τ = Pshaft/(2πN/60)

Use kg/s for ṁ and watts for the SI torque equation. Torque is at the screw shaft, after the drive losses used to estimate motor size.

References