Worked example · Screw Conveyor

20° sand transfer auger

A short-pitch auger raises sand from a hopper to the next transfer point. The advance per revolution is shorter than the flight OD.

Live results

Auger flight, pitch and loaded annulus

Edit inputs
Auger flight, pitch and loaded annulus Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. VOLUME RATE883.63CFHMASS RATE41.97TPHSHAFT TORQUE4732.52lb-inMOTOR POWER7.17HP AUGER FLIGHTTROUGH SECTIONFlowPitch 9.33 in20° inclineFlight OD 14 in22.5% effective fill Incline capacity retained75%Compared with the same screw operating horizontally.

Compared with the same screw operating horizontally.

All calculated values
Volume throughput
883.625CFH
Mass throughput
41.972TPH
Screw shaft torque
4,732.525lb-in
Motor power
7.168HP
Open flight annulus
1.002ft²
Incline capacity retained
75%
Effective fill after derate
22.5%
Diameter factor
78
Empty screw power
0.157HP
Material power before multiplier
4.835HP
Vertical rise
8.208ft
Gravity lift power
0.348HP
Screw shaft power
6.307HP

Inputs

Unit system
Operating inputs
in
in
in
RPM
°
ft
lb/ft³
Drive & model factors
%
0 applies the angle-based estimate. Enter a measured percentage to override it.
Enter an OEM overload or fallback allowance if known.
%

Worked solution

Starting case in US units

  1. Subtract the 3.5 in shaft from the 14 in flight envelope to get an open area of 1 ft².
  2. With 9.33 in pitch, 84 RPM, 30% loading and 75% retained capacity, the auger moves 883.63 CFH or 41.97 TPH.
  3. Add empty, corrected material and gravity power. The screw shaft uses 6.31 HP and 4732.52 lb-in at the entered speed.

Try it. Compare operation at 20° and at 0°. The retained fraction and gravity power change in opposite directions.

More worked examples

Open a different starting case

Equations and assumptions

Annular displacement and incline

Qᵥ = (π/4)(D² − d²) · p · N · 60 · f · k

D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.

Empty and material horsepower

HPf = Fd Fb L N / 10⁶   |   HPm = ṁ Fm L / 10⁶

The KWS control-fed convention uses L in feet, ṁ in lb/h and empirical diameter, hanger and material factors. Diameter factor is interpolated through the published screw diameters. The optional multiplier applies to material power. Obtain OEM correction for low material HP, startup and flood feeding.

Gravity, motor and shaft torque

Plift = ṁ g L sin α   |   Pshaft = Pf + multiplier · Pm + Plift
Pmotor = Pshaft/η   |   τ = Pshaft/(2πN/60)

Use kg/s for ṁ and watts for the SI torque equation. Torque is at the screw shaft, after the drive losses used to estimate motor size.

References