D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.
Empty and material horsepower
HPf = Fd Fb L N / 10⁶ | HPm = ṁ Fm L / 10⁶
The KWS control-fed convention uses L in feet, ṁ in lb/h and empirical diameter, hanger and material factors. Diameter factor is interpolated through the published screw diameters. The optional multiplier applies to material power. Obtain OEM correction for low material HP, startup and flood feeding.
Gravity, motor and shaft torque
Plift = ṁ g L sin α | Pshaft = Pf + multiplier · Pm + Plift
Pmotor = Pshaft/η | τ = Pshaft/(2πN/60)
Use kg/s for ṁ and watts for the SI torque equation. Torque is at the screw shaft, after the drive losses used to estimate motor size.
Compared with the same screw operating horizontally.
Inputs
Screw OD
24 in
Pipe shaft OD
6 in
Flight pitch
18 in
Trough loading
30%
Screw speed
30 RPM
Incline angle
8°
Conveyor length
49 ft
Bulk density
115 lb/ft³
Incline capacity retained
0%
Material factor Fm
3.6
Hanger bearing factor
2
Material power multiplier
1.5
Drive efficiency
88%
Calculated values
Volume throughput
2,290.221CFH
Mass throughput
131.688TPH
Screw shaft torque
149,763.269lb-in
Motor power
81.008HP
Open flight annulus
2.945ft²
Incline capacity retained
96%
Effective fill after derate
28.8%
Diameter factor
235
Empty screw power
0.691HP
Material power before multiplier
46.459HP
Vertical rise
6.819ft
Gravity lift power
0.907HP
Screw shaft power
71.287HP
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.