The sensible terms use temperature changes above and below the freezing point. A batch starting below freezing uses only the last term. A batch stopping at the freezing point ends before the latent stage in this model.
Estimated core pull-down
t = Etotal / (3,600 × Qrated × effectiveness)
For E in kJ and Q in kW the answer is hours. Pack geometry, access to air, and surface/core gradients are folded into one estimated effectiveness. Validate core temperatures with probes under the intended loading.
What should I check in the chilling to the freezing threshold example?
An endpoint equal to the freezing point has zero latent load in the model. Set a lower endpoint to include the freezing stage.
ColdChainLab · Engineering calculation
Chilling to the freezing threshold
Metric SI · https://calcsheetlab.com/coldchainlab/blast-chiller-freezing-time/chill-to-freezing-edge/
Inputs
Batch mass
175 kg
Initial core temperature
9 °C
Target core temperature
-1.5 °C
Product freeze point
-1.5 °C
Specific heat above freezing
3.7 kJ/(kg·K)
Specific heat below freezing
1.8 kJ/(kg·K)
Latent heat of fusion
252 kJ/kg
Rated refrigeration capacity
12 kW
Effective batch capacity
72 %
Results
Pull-down time
0.22h
Heat removed
6,799kJ
Effective rate
8.64kW
Freeze time
0h
Sensible heat above freezing
6,799kJ
Heat of fusion
0kJ
Sensible heat below freezing
0kJ
Heat per unit mass
38.85kJ/kg
Time above freezing
0.22h
Time below freezing
0h
Use these estimates for preliminary engineering. Verify results against validated cold-chain qualification protocols, applicable ASHRAE Standards 15 and 34, and local food and pharmaceutical regulations. Use manufacturer data, measured operating conditions, and approved acceptance criteria before acting on a result.