Worked example · Product cooling

Chilling to the freezing threshold

A process cools product to the stated initial freezing point and stops before deliberately freezing it.

Pull-down time
0.22h
Heat removed
6,799kJ
Effective rate
8.64kW
Freeze time
0h
Edit inputs

Inputs

Edit any value to recalculate.

Batch & temperatures
kg
°C
°C
°C
Product properties
kJ/(kg·K)
kJ/(kg·K)
kJ/kg
Equipment

Enter refrigeration output at the actual operating condition. The percentage is the share available to remove product heat.

kW
%

Core temperature pull-down

Core temperature pull-downA constant effective capacity turns each sensible or latent heat term into the length of its stage.Core temperature / °CElapsed time / h00.10.10.20.2-2.81.65.910.3Above freezePhase changeBelow freeze

A constant effective capacity turns each sensible or latent heat term into the length of its stage.

Calculation breakdown

Sensible heat above freezing
6,799kJ
Heat of fusion
0kJ
Sensible heat below freezing
0kJ
Heat per unit mass
38.85kJ/kg
Time above freezing
0.22h
Time below freezing
0h

Work through this case

  1. Time above freezing 0.22h
  2. Freeze time 0h
  3. Pull-down time 0.22h

An endpoint equal to the freezing point has zero latent load in the model. Set a lower endpoint to include the freezing stage.

More worked examples

Open a case with its assumptions loaded, then edit the inputs.

Open base calculator

Formulas and assumptions

Three-stage batch enthalpy

Etotal = m × c₊ΔT₊ + m × Lf + m × c₋ΔT₋

The sensible terms use temperature changes above and below the freezing point. A batch starting below freezing uses only the last term. A batch stopping at the freezing point ends before the latent stage in this model.

Estimated core pull-down

t = Etotal / (3,600 × Qrated × effectiveness)

For E in kJ and Q in kW the answer is hours. Pack geometry, access to air, and surface/core gradients are folded into one estimated effectiveness. Validate core temperatures with probes under the intended loading.

References

Questions and answers

What should I check in the chilling to the freezing threshold example?

An endpoint equal to the freezing point has zero latent load in the model. Set a lower endpoint to include the freezing stage.