Worked example · Product cooling

Blast chilling cooked meals

A tray batch is cooled from a hot initial core temperature to a chilled endpoint above freezing.

Pull-down time
0.86h
Heat removed
27,188kJ
Effective rate
8.8kW
Freeze time
0h
Edit inputs

Inputs

Edit any value to recalculate.

Batch & temperatures
kg
°C
°C
°C
Product properties
kJ/(kg·K)
kJ/(kg·K)
kJ/kg
Equipment

Enter refrigeration output at the actual operating condition. The percentage is the share available to remove product heat.

kW
%

Core temperature pull-down

Core temperature pull-downA constant effective capacity turns each sensible or latent heat term into the length of its stage.Core temperature / °CElapsed time / h00.20.40.70.9-3214569Above freezePhase changeBelow freeze

A constant effective capacity turns each sensible or latent heat term into the length of its stage.

Calculation breakdown

Sensible heat above freezing
27,188kJ
Heat of fusion
0kJ
Sensible heat below freezing
0kJ
Heat per unit mass
217.5kJ/kg
Time above freezing
0.86h
Time below freezing
0h

Work through this case

  1. Sensible heat above freezing 27,188kJ
  2. Heat removed 27,188kJ
  3. Pull-down time 0.86h

Only the above-freezing stage contributes in this input range. A core-temperature probe in the slowest tray is needed to validate timing.

More worked examples

Open a case with its assumptions loaded, then edit the inputs.

Open base calculator

Formulas and assumptions

Three-stage batch enthalpy

Etotal = m × c₊ΔT₊ + m × Lf + m × c₋ΔT₋

The sensible terms use temperature changes above and below the freezing point. A batch starting below freezing uses only the last term. A batch stopping at the freezing point ends before the latent stage in this model.

Estimated core pull-down

t = Etotal / (3,600 × Qrated × effectiveness)

For E in kJ and Q in kW the answer is hours. Pack geometry, access to air, and surface/core gradients are folded into one estimated effectiveness. Validate core temperatures with probes under the intended loading.