Worked example · Product cooling

Three-stage freezing of fish fillets

Fish fillets enter above freezing and leave at a deeply frozen core target, with all three energy stages active.

Pull-down time
1.38h
Heat removed
93,643kJ
Effective rate
18.85kW
Freeze time
1.05h
Edit inputs

Inputs

Edit any value to recalculate.

Batch & temperatures
kg
°C
°C
°C
Product properties
kJ/(kg·K)
kJ/(kg·K)
kJ/kg
Equipment

Enter refrigeration output at the actual operating condition. The percentage is the share available to remove product heat.

kW
%

Core temperature pull-down

Core temperature pull-downA constant effective capacity turns each sensible or latent heat term into the length of its stage.Core temperature / °CElapsed time / h00.40.71.11.4-27.8-14.6-1.411.8Above freezePhase changeBelow freeze

A constant effective capacity turns each sensible or latent heat term into the length of its stage.

Calculation breakdown

Sensible heat above freezing
10,863kJ
Heat of fusion
71,400kJ
Sensible heat below freezing
11,380kJ
Heat per unit mass
312.14kJ/kg
Time above freezing
0.16h
Time below freezing
0.17h

Work through this case

  1. Sensible heat above freezing 10,863kJ
  2. Heat of fusion 71,400kJ
  3. Sensible heat below freezing 11,380kJ

Use the phase-change term for the actual fish composition. A high latent term lengthens the plateau even if the sensible drops are small.

More worked examples

Open a case with its assumptions loaded, then edit the inputs.

Open base calculator

Formulas and assumptions

Three-stage batch enthalpy

Etotal = m × c₊ΔT₊ + m × Lf + m × c₋ΔT₋

The sensible terms use temperature changes above and below the freezing point. A batch starting below freezing uses only the last term. A batch stopping at the freezing point ends before the latent stage in this model.

Estimated core pull-down

t = Etotal / (3,600 × Qrated × effectiveness)

For E in kJ and Q in kW the answer is hours. Pack geometry, access to air, and surface/core gradients are folded into one estimated effectiveness. Validate core temperatures with probes under the intended loading.

References

Questions and answers

What should I check in the three-stage freezing of fish fillets example?

Use the phase-change term for the actual fish composition. A high latent term lengthens the plateau even if the sensible drops are small.