Worked example

Overload compression coupon

Apply a running load above the elastic plate buckling threshold.

The plate status changes at unit reserve. The output covers bifurcation and gives no estimate of postbuckling strength.

View live results

Inputs

Plate geometry and load
mm
mm
N/mm
Bending stiffness
N·mm
N·mm
N·mm
N·mm

Live results

SI
Plate critical
36.549 N/mm
Euler strip
6.4584 N/mm
Half-waves
1
Load margin
−0.75634
FailSSSS plate threshold
Buckling mode branches
Orthotropic buckling coefficient mode branches with active aspect ratio k0.56a/bm* = 1
  • Minimum of 16 modes
  • Modes 1–5
  • Active aspect
Limit utilization410.41%
0%100% limit

Plate stability

Aspect ratio a/b
1.57692
Coefficient k
3.55813
Plate reserve factor
0.243661
Euler strip reserve
0.043056
D11
110,000 N·mm
D12
12,500 N·mm
D22
45,000 N·mm
D66
17,300 N·mm

Axial half-wave sweep

Mode mCritical running load
136.5491 N/mm
243.6712 N/mm
373.6941 N/mm
4118.109 N/mm
5175.867 N/mm
6246.709 N/mm
7330.548 N/mm
8427.346 N/mm
9537.085 N/mm
10659.756 N/mm
11795.354 N/mm
12943.876 N/mm
131,105.32 N/mm
141,279.68 N/mm
151,466.97 N/mm
161,667.17 N/mm

Model and assumptions

Nx,cr(m) = (π²/b²)[D₁₁(mb/a)² + 2(D₁₂ + 2D₆₆) + D₂₂(a/mb)²].

The plate has four simply supported edges, compression along a and one transverse half-wave. The table sweeps m = 1 through 16. If the minimum lies beyond mode 16, the two integers around the analytical minimum are checked for the governing threshold.

Direct inputs require positive-definite, specially orthotropic bending stiffness. The 0° single-layer option uses D = Qh³/12. The plot normalizes critical load as k = Nx,cr·b²/(π²√(D₁₁D₂₂)).

The pin-ended, unit-width strip value π²D₁₁/a² is a comparison. For a strip with width b the corresponding total axial force is its running load times b.

Scope. Linear bifurcation with D₁₆ = D₂₆ = 0 and no extension–bending coupling, imperfection, transverse shear or postbuckling strength.

See calculation methods and references