Heavy #6 rebar for a 16 × 12 ft pump pad
A pump foundation pad has a straight #6 mat at up to 8 in centers. Material on hand is in 12 ft lengths, and the takeoff uses a 48d overlap.
Estimate
Rebar weight incl. laps
- Counts assume one straight mat. Confirm cover, development, stagger and lap with the structural drawings.
- Weight · equivalent
- 435.35 kg
- Continuous grid runs
- 44
- Runs along X
- 19
- Runs along Y
- 25
- Actual X center spacing
- 7.72 in
- Actual Y center spacing
- 7.63 in
- Lap per splice
- 36 in
- Lap joints
- 19
- Stock pieces before offcut reuse
- 63
- Grid intersections
- 475
- Length before laps
- 582 ft
- Cut length incl. laps
- 639 ft
- Cut length · equivalent
- 194.767 m
Download
Working this example
Starting estimate 959.78 lbRebar weight incl. laps
Coordinate the mat with the actual equipment anchor layout and add trimming steel or localized reinforcement from the detail.
Questions & answers
Does the 12 ft stock fit the short pump-pad runs?
Yes. The ends of a run across the 12 ft width stop at the clear cover, so its cut length is below 12 ft.
What overlap should be budgeted per #6 joint at 48d?
A #6 bar is nominally ¾ in in diameter. A 48d estimating lap adds 36 in to each joint.