ConcreteEarthLab

Worked example

Heavy #6 rebar for a 16 × 12 ft pump pad

A pump foundation pad has a straight #6 mat at up to 8 in centers. Material on hand is in 12 ft lengths, and the takeoff uses a 48d overlap.

Inputs

Measurement system
ft
ft
in
Center to center for bars running along Y.
in
Center to center for bars running along X.
in
ft
Common stock lengths are 20 ft and 6 m. Set the length your supplier carries.
d
Use the lap from the structural drawings when available.
SLAB REBAR MATPlan of bar runs, clear cover, and the two spacing directions. SLAB REBAR MAT X 16 ftY 12 ft#6 · 19 along X · 25 along Y19 laps

Estimate

Rebar weight incl. laps
959.78 lb
  • Counts assume one straight mat. Confirm cover, development, stagger and lap with the structural drawings.
Weight · equivalent
435.35 kg
Continuous grid runs
44
Runs along X
19
Runs along Y
25
Actual X center spacing
7.72 in
Actual Y center spacing
7.63 in
Lap per splice
36 in
Lap joints
19
Stock pieces before offcut reuse
63
Grid intersections
475
Length before laps
582 ft
Cut length incl. laps
639 ft
Cut length · equivalent
194.767 m
Download

Working this example

Starting estimate 959.78 lbRebar weight incl. laps

Coordinate the mat with the actual equipment anchor layout and add trimming steel or localized reinforcement from the detail.

See the calculator formulas and assumptions

Questions & answers

Does the 12 ft stock fit the short pump-pad runs?

Yes. The ends of a run across the 12 ft width stop at the clear cover, so its cut length is below 12 ft.

What overlap should be budgeted per #6 joint at 48d?

A #6 bar is nominally ¾ in in diameter. A 48d estimating lap adds 36 in to each joint.