ControlLoopLab
Home Digital filtersWorked example

Load cell low-pass group delay

A weigh scale stabilization cycle is sensitive to how much the signal chain delays changes.

Model inputs

Filter specification
Hz
Hz
Hz

Discrete transfer & step samples

Below Nyquist
Cutoff gain
−3.0103dB
Test phase
−7.5892°
Test delay
10.418ms
Noise BW
22.518Hz
Discrete low-pass attenuation and step responseDiscrete attenuationdB1.255.5925112500−72−47−223Frequency (Hz, log)Unit-step samplesoutput014.829.544.359−0.080.3070.6931.08Sample index nCutoff markerTest markerStep samples
y[n] = b0 x[n] + b1 x[n−1] + b2 x[n−2] − a1 y[n−1] − a2 y[n−2]

Calculated results

b0
0.045035005911131264
b1
0.045035005911131264
b2
0
a1
-0.9099299881777375
a2
0
DC gain
1×
Cutoff attenuation
−3.0103dB
Cutoff phase
−45°
Cutoff group delay
5.313samples
Cutoff group delay
5.313ms
Test attenuation
−0.076419dB
Test phase
−7.5892°
Test group delay
10.418samples
Test group delay
10.418ms
95% first crossing
32ms
99% first crossing
49ms
Equivalent noise bandwidth
22.518Hz

Model and interpretation

Full methodology

Set cutoff in digital frequency

Cutoff is strictly between DC and Nyquist. EMA uses the exact digital half-power coefficient. Tustin and Butterworth prewarp the cutoff before bilinear conversion. The denominator uses a0 = 1 and the negative-feedback convention shown above.

Read phase and delay separately

Phase is ∠H(eʲω). Group delay is −d∠H/dω in samples and can differ sharply from phase delay. At a Nyquist transmission zero the displayed phase is the one-sided limit. The noise bandwidth is the one-sided integral of |H|² at unity DC.

Check how the firmware represents it

Step times show the first sample at or past 95% and 99%, with the input step at n = 0. Near DC or Nyquist, implement a suitable factored or high-precision realization and recheck coefficient quantization.