Methodology

Equations, input conventions and screening limits for the eight CorrosionRateLab calculators.

Weight-loss corrosion rateRemaining life & UT intervalB31G pipeline strengthSacrificial anode sizingICCP groundbed resistanceICCP rectifier sizingPREN & galvanic area ratioCO₂ sweet corrosion rate

Using a screen in an engineering review

Confirm material, geometry, measurement uncertainty and applicable standards before using a result for design or operations. A site-specific assessment is required to establish inspection dates, regulatory pressure limits or corrosion protection criteria.

Weight-loss corrosion rate

Open calculator
  1. Normalize the exposure

    Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.

  2. Calculate penetration and areal loss

    Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.

  3. Convert using equivalent weight

    The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.

Remaining life & UT interval

Open calculator
  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule

    Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.

B31G pipeline strength

Open calculator
  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.

Sacrificial anode sizing

Open calculator
  1. Estimate demand at three stages

    For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².

  2. Calculate net alloy mass

    M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.

  3. Check final and initial current

    For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.

ICCP groundbed resistance

Open calculator
  1. Estimate a single anode

    For a shallow vertical electrode, R = ρ[ln(8L/d) − 1]/(2πL). Use the conductive coke column diameter and length when it functions as an equivalent electrode.

  2. Apply trench depth if horizontal

    With centerline depth h, set s = 2h and q = √(s² + L²). Dwight’s horizontal bracket is ln[4L(L + q)/(d × s)] + (s − q)/L − 1. Multiply by ρ/(2πL).

  3. Estimate row interaction

    With N > 1, add ρ × ln(0.656N)/(πNS) to R_single/N for center spacing S. This Sunde term is for a vertical row. Applying it to parallel horizontal trenches is an approximation. The voltage drop is design current × modeled bed resistance.

ICCP rectifier sizing

Open calculator
  1. Build the DC voltage budget

    Required voltage = current × (groundbed + structure + loop cable resistance) + opposing back-EMF. Multiply by the design factor for the minimum design voltage.

  2. Check the tap and AC supply

    Use the first listed tap at or above the design voltage, or enter a nameplate tap. DC kW = operating voltage × current ÷ 1,000. AC kW = DC kW ÷ efficiency. AC kVA = AC kW ÷ power factor. Rated load at the selected tap is shown separately.

  3. Estimate running cost

    AC kW × annual runtime gives kWh/yr. Multiply by the entered tariff for annual cost. Headroom is (tap − operating voltage) ÷ operating voltage.

PREN & galvanic area ratio

Open calculator
  1. Calculate each composition index

    Standard PREN = Cr + 3.3Mo + 16N. With tungsten use PREN_W = Cr + 3.3(Mo + 0.5W) + 16N. Enter each element in mass percent.

  2. Read the comparison bands

    The bands are below 25, 25 to below 32, 32 to 40 inclusive, and above 40. The highest band denotes a seawater candidate for further assessment.

  3. Compare the exposed areas

    The proxy multiplies the uncoupled anode rate by max(1, cathode/anode area). Area contrast is low up to 1, raised above 1 through 10, and high above 10. These are comparison bands for the area effect.

CO₂ sweet corrosion rate

Open calculator
  1. Find CO₂ partial pressure

    Multiply absolute pressure in bar by the gas-phase CO₂ mole fraction. Convert temperature to kelvin before evaluating either equation.

  2. Correct for fugacity

    log₁₀(a) = (0.0031 − 1.4/T_K) × P_bar. The fugacity f is a × P_CO₂. The uninhibited rate is 10^[5.8 − 1710/T_K + 0.67 log₁₀(f)] in mm/yr. Zero CO₂ gives a zero term directly.

  3. Apply the chosen net credit

    Multiply by (1 − η), where η is the credited efficiency fraction for a pH effect, protective scale, inhibitor or their measured combined effect. Convert mm/yr to mpy by dividing by 0.0254.

Units and unavailable values

US and SI views use the same stored input values. A dash indicates an unavailable, inapplicable or withheld result. Exports include unrounded model values. Worked examples are illustrative and editable.