Sacrificial Anode Weight and Count Calculator
Size galvanic anodes by net alloy mass and final current output, then check initial polarization and estimated capacity life.
Inputs
SI unitsEnter bare-metal design current density for each phase and its associated coating breakdown. Use final stand-off anode dimensions.
- Required mass
- 1,236.71 kg
- Anodes needed
- 23
- Output / anode
- 2.65 A
- Capacity life
- 25.57 yr
Galvanic current field
SchematicConfirm final geometry, closed-circuit potentials, coating allowances and current distribution with the CP design basis.
Calculation details
- Alloy design capacity
- 2,000 A·h/kg
- Initial demand
- 7.68 A
- Mean demand
- 9.6 A
- Final demand
- 28.8 A
- Final single-anode resistance
- 0.0942 Ω
- Count by net mass
- 23
- Count by final current
- 11
- Count for initial polarization
- 3
- Installed net mass
- 1,265 kg
- Total installed current output
- 61.04 A
Inputs used
- Anode alloy
- Aluminum–zinc–indium
- Protected area
- 1,200 m²
- Design life
- 25 yr
- Initial breakdown
- 4 %
- Initial bare demand
- 160 mA/m²
- Mean breakdown
- 8 %
- Mean bare demand
- 100 mA/m²
- Final breakdown
- 15 %
- Final bare demand
- 160 mA/m²
- Utilization
- 85 %
- Net mass per anode
- 55 kg
- Final anode length
- 1.6 m
- Final equiv. radius
- 0.08 m
- Driving voltage ΔE
- 0.25 V
- Electrolyte resistivity
- 0.28 Ω·m
Method and limits
Estimate demand at three stages
For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².
Calculate net alloy mass
M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.
Check final and initial current
For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.