CorrosionRateLab
Menu

Sacrificial Anode Weight and Count Calculator

Size galvanic anodes by net alloy mass and final current output, then check initial polarization and estimated capacity life.

Inputs

SI units

Enter bare-metal design current density for each phase and its associated coating breakdown. Use final stand-off anode dimensions.

m²
yr
%
mA/m²
%
mA/m²
%
mA/m²
%
kg
m
m
V
Ω·m
Required mass
1,236.71 kg
Anodes needed
23
Output / anode
2.65 A
Capacity life
25.57 yr

Galvanic current field

Schematic
Galvanic current field (schematic, not to scale)Anode metalProtected steelConventional current through electrolyteDRIVING VOLTAGE0.25 VFINAL DEMAND28.8 AANODE OUTPUT2.65 A
Anode mass governs

Confirm final geometry, closed-circuit potentials, coating allowances and current distribution with the CP design basis.

Final demand ÷ modeled installed output

Calculation details

Alloy design capacity
2,000 A·h/kg
Initial demand
7.68 A
Mean demand
9.6 A
Final demand
28.8 A
Final single-anode resistance
0.0942 Ω
Count by net mass
23
Count by final current
11
Count for initial polarization
3
Installed net mass
1,265 kg
Total installed current output
61.04 A

Method and limits

  1. Estimate demand at three stages

    For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².

  2. Calculate net alloy mass

    M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.

  3. Check final and initial current

    For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.