CorrosionRateLab
Menu

ICCP Groundbed Resistance Calculator

Estimate vertical or horizontal groundbed resistance, mutual interference and operating voltage drop with optional coke backfill.

Inputs

SI units

Use surrounding soil resistivity. For low-resistance coke backfill, the optional effective diameter is the column outside diameter.

Ω·m
m
m
m
m
A
Ω
Groundbed
0.895 Ω
Single anode
7.022 Ω
Crowding
1.53 ×
Bed drop
16.12 V

Anode field and interaction

Schematic
Anode field and interaction (schematic, not to scale)Vertical row4 of 12 anodesEFFECTIVE Ø0.18 mCENTER SPACING6 mROW RESISTANCE0.895 Ω
Within resistance target

Verify field resistivity, backfill contact and actual current distribution before sizing a rectifier.

Modeled resistance ÷ selected target

Calculation details

Effective anode diameter
0.18 m
Ideal parallel resistance
0.5851 Ω
Mutual resistance term
0.3101 Ω
Total modeled resistance
0.8953 Ω
Target minus modeled resistance
0.1047 Ω
Ideal-parallel efficiency
65.36 %

Method and limits

  1. Estimate a single anode

    For a shallow vertical electrode, R = ρ[ln(8L/d) − 1]/(2πL). Use the conductive coke column diameter and length when it functions as an equivalent electrode.

  2. Apply trench depth if horizontal

    With centerline depth h, set s = 2h and q = √(s² + L²). Dwight’s horizontal bracket is ln[4L(L + q)/(d × s)] + (s − q)/L − 1. Multiply by ρ/(2πL).

  3. Estimate row interaction

    With N > 1, add ρ × ln(0.656N)/(πNS) to R_single/N for center spacing S. This Sunde term is for a vertical row. Applying it to parallel horizontal trenches is an approximation. The voltage drop is design current × modeled bed resistance.