Remaining Life and Inspection Interval Calculator
Use repeat ultrasonic thickness readings to estimate retirement margin, remaining life and a capped half-life inspection interval.
Inputs
SI unitsUse comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.
- Governing rate
- 0.26 mm/yr
- Wall margin
- 2 mm
- Remaining life
- 7.69 yr
- UT interval
- 3.85 yr
UT thickness history
SchematicConfirm the governing rates, inspection method, service class and current code before setting a due date.
Calculation details
- Short-term thinning rate
- 0.26 mm/yr
- Long-term thinning rate
- 0.24 mm/yr
- Years between UT readings
- 5 yr
- Governing thinning rate
- 0.26 mm/yr
- Half-life before cap
- 3.85 yr
- Screened inspection interval
- 3.85 yr
Inputs used
- Previous UT thickness
- 9.6 mm
- Previous year
- 2,020
- Current UT thickness
- 8.3 mm
- Current year
- 2,025
- Retirement thickness
- 6.3 mm
- Installed thickness
- 11.7 mm
- Years in service
- 14 yr
- Inspection cap preset
- API 570 Class 1 · 5 yr
- Maximum interval
- 5 yr
Method and limits
Compare short and long histories
Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.
Measure the retirement margin
Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.
Apply the half-life rule
Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.