ASME B30.5 · OSHA 1926.1402

Crane Outrigger Ground Bearing

Compare a peak outrigger reaction with assumed pad contact area and the allowable pressure for the set-up location.

Inputs

Peak reaction
lb
lb
lb
%
Pad and ground
ft
in
in
psf
Use the verified allowable for this crane set-up.
Back to results ↑

Results

Static screeningEdit inputs ↓
Outrigger and mat sectionPEAK REACTION80,000lbfGROUND PRESS2,812.5psfBEARING AREA28.44ft²SOIL USE89.78%JACK REACTION45° spreadMatSoilEffective contactSoil bearing limit89.78%Applied reactionMat load spreadGround contactLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results
  • Estimated corner share selected. Use the peak OEM reaction for the complete lift path.
  • The 45° spread reaches only part of the pad footprint in this model.
Peak reaction at one pad
80,000 lbf
Effective ground pressure
2,812.5 psf
Effective bearing area
28.44 ft²
Allowable pressure used
89.78 %
Effective pressure in psi
19.53 psi
Full-footprint pressure
2,222.22 psf
Effective width or diameter
5.33 ft
Area needed at entered limit
25.54 ft²
Entered allowable pressure
3,132.82 psf

Peak corner reaction

R = (Wcrane + Wload + Wrigging) × f

Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.

Effective contact

Dₑ = min(Dpad, Dfoot + 2t)

Assume centered load and a 45° spread through the mat thickness t. Apply the limit on each rectangular axis. For round pads use πDₑ²/4.

Bearing pressure

p = R / Aₑ

Compare with the site-specific allowable pressure. Full-pad pressure is a reference and assumes complete load distribution.

Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.