ASME B30.5 · OSHA 1926.1402

Mat thick enough to reach full width

A 72,000 lbf OEM reaction lands on a 5 ft wide mat through a 30 in square jack foot.

Inputs

Peak reaction
lbf
Pad and ground
ft
in
in
Back to results ↑

Results

Static screeningEdit inputs ↓
Outrigger and mat sectionPEAK REACTION72,000lbfGROUND PRESS2,880psfBEARING AREA25ft²SOIL USE137.9%JACK REACTION45° spreadMatSoilEffective contactSoil bearing limit137.9%Applied reactionMat load spreadGround contactLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • Estimated bearing pressure exceeds the selected allowable pressure.
  • Illustrative soil value selected. Obtain the allowable bearing pressure for this location.
Peak reaction at one pad
72,000 lbf
Effective ground pressure
2,880 psf
Effective bearing area
25 ft²
Allowable pressure used
137.9 %
Effective pressure in psi
20 psi
Full-footprint pressure
2,880 psf
Effective width or diameter
5 ft
Area needed at entered limit
34.47 ft²
Entered allowable pressure
2,088.54 psf

With 20 in of mat thickness the projected width exceeds the footprint. Cap effective area at the physical mat area.

Peak reaction at one pad 72,000 lbf · Effective ground pressure 2,880 psf

Peak corner reaction

R = (Wcrane + Wload + Wrigging) × f

Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.

Effective contact

Dₑ = min(Dpad, Dfoot + 2t)

Assume centered load and a 45° spread through the mat thickness t. Apply the limit on each rectangular axis. For round pads use πDₑ²/4.

Bearing pressure

p = R / Aₑ

Compare with the site-specific allowable pressure. Full-pad pressure is a reference and assumes complete load distribution.

Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.