ASME B30.20 · ASME BTH-1

Lifting beam screening moment exceeded

A 31,000 lb package hangs at two end pickups on a 16 ft center-picked beam with an entered 115,000 lbf·ft moment limit.

Inputs

Load and geometry
lb
ft
°
ft
lbf·ft
Spreader pipe properties
in
in
Msi
ksi
×
×
Back to results ↑

Results

Static screeningEdit inputs ↓
Spreader and lifting beam free bodiesCOMPRESSION12,109.93lbfBEAM MOMENT124,000lbf·ftEULER LOAD562,966lbfHEIGHT SAVED8.24ftSPREADER BARLIFTING BEAMAXIAL COMPRESSIONCENTER BENDINGSpreader axial limit14.96%Beam moment limit107.83%Sling tensionMember reactionReference or heightLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • Beam bending demand exceeds the entered moment limit.
Spreader axial compression
12,109.93 lbf
Lifting beam peak bending
124,000 lbf·ft
Ideal Euler buckling load
562,965.59 lbf
Headroom saved with beam
8.24 ft
Pipe slenderness, KL/r
65.36
E3 axial load at screening factor
80,947.73 lbf
Tension per upper sling
19,669.78 lbf
Spreader hook rise above pickup
10.24 ft

Compare center bending with the entered limit. The separate axial screen applies to the alternative spreader.

Spreader axial compression 12,109.93 lbf · Lifting beam peak bending 124,000 lbf·ft

Spreader force

C = (W/2) / tan θ

Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).

Pipe buckling

Pₑ = π²EI / (KL)²

The AISC E3 flexural column curve reduces elastic or inelastic strength for a non-slender round steel section. Divide its nominal strength by the entered screening factor.

Beam comparison

M = WL/4; ΔH = (L/2) tan θ − Hbeam

Assume symmetrical end forces and a single center pick. Compare equal reference points for headroom.

Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.