ASME B30.20 · ASME BTH-1

Long pipe spreader with high slenderness

A 7.2 m long pipe spreader carries a 17,000 kg load. The pipe outside diameter is 114.3 mm and the wall is 5.5 mm.

Inputs

Load and geometry
kg
m
°
m
kN·m
Spreader pipe properties
mm
mm
GPa
MPa
×
×
Back to results ↑

Results

Static screeningEdit inputs ↓
Spreader and lifting beam free bodiesCOMPRESSION92.58kNBEAM MOMENT300.08kN·mEULER LOAD106.19kNHEIGHT SAVED2.63mSPREADER BARLIFTING BEAMAXIAL COMPRESSIONCENTER BENDINGSpreader axial limit298.22%Beam moment limit93.78%Sling tensionMember reactionReference or heightLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • Spreader compression exceeds the E3 axial screening limit.
Spreader axial compression
92.58 kN
Lifting beam peak bending
300.08 kN·m
Ideal Euler buckling load
106.19 kN
Headroom saved with beam
2.63 m
Pipe slenderness, KL/r
186.94
E3 axial load at screening factor
31.04 kN
Tension per upper sling
124.57 kN
Spreader hook rise above pickup
3.24 m

The effective length enters Euler load as a square. Compare compression with the reduced axial screen.

Spreader axial compression 92.58 kN · Lifting beam peak bending 300.08 kN·m

Spreader force

C = (W/2) / tan θ

Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).

Pipe buckling

Pₑ = π²EI / (KL)²

The AISC E3 flexural column curve reduces elastic or inelastic strength for a non-slender round steel section. Divide its nominal strength by the entered screening factor.

Beam comparison

M = WL/4; ΔH = (L/2) tan θ − Hbeam

Assume symmetrical end forces and a single center pick. Compare equal reference points for headroom.

Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.

Other worked examples