Peak corner reaction
R = (Wcrane + Wload + Wrigging) × f
Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.
ASME B30.5 · OSHA 1926.1402
The crane manufacturer gives a peak 270 kN jack reaction. The selected circular pad is 1.8 m in diameter.
Schematic geometry. Margin bars mark 100% of the entered limit.
Use the circular area of the smaller spread diameter. The resulting effective pressure can exceed the full-pad reference.
Peak reaction at one pad 270 kN · Effective ground pressure 188.63 kPa
R = (Wcrane + Wload + Wrigging) × f
Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.
Dₑ = min(Dpad, Dfoot + 2t)
Assume centered load and a 45° spread through the mat thickness t. Apply the limit on each rectangular axis. For round pads use πDₑ²/4.
p = R / Aₑ
Compare with the site-specific allowable pressure. Full-pad pressure is a reference and assumes complete load distribution.
Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.
CraneRiggingLab · Lift screening worksheet
ASME B30.5 · OSHA 1926.1402 · SI · kg
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.