Leg tension
T = W / (n × sin θ)
Measure θ from horizontal. In a vertical or single choker hitch, use θ = 90°.
ASME B30.9 · OSHA 1926.251
A 4,400 lb mechanical package must pass through an opening with little room above the pickups. The proposed angle is 22°.
Schematic geometry. Margin bars mark 100% of the entered limit.
Review both capacity and angle. A generous tagged WLL does not remove the low-angle warning.
Tension per carrying leg 5,872.83 lbf · Sling angle load factor 2.67 ×
T = W / (n × sin θ)
Measure θ from horizontal. In a vertical or single choker hitch, use θ = 90°.
Basket WLL = 2 × WLL₀ × sin θ
Bridle WLL uses the effective leg count and the same sine factor. Apply the choke-angle multiplier to the tagged wire-rope choker WLL. With no tagged choker WLL, 0.75 × WLL₀ is illustrative.
H = r × tan θ
r is the horizontal reach from the hook centerline to a pickup. At 90°, use the measured drop. A multi-leg 90° case assumes parallel legs with matching upper supports.
Compare with the tagged assembly WLL for the actual material, hitch, angle, number of legs, fittings and bend radius. Use the lower approved limit. Have a qualified person verify load sharing and the assumptions for rigid loads.
CraneRiggingLab · Lift screening worksheet
ASME B30.9 · OSHA 1926.251 · US · lb
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Compare with the tagged assembly WLL for the actual material, hitch, angle, number of legs, fittings and bend radius. Use the lower approved limit. Have a qualified person verify load sharing and the assumptions for rigid loads.