ASME B30.9 · OSHA 1926.251

Vertical single-leg lift for a pump

A pump with one engineered top lifting point weighs 6,000 lb. The sling hangs vertically with 7 ft of clear drop.

Inputs

Load and sling
lb
lb
Geometry
ft
Back to results ↑

Results

Static screeningEdit inputs ↓
Sling arrangementLEG TENSION6,000lbfANGLE FACTOR1×HEADROOM7ftHITCH WLL7,500lbSUSPENDED LOADHOOKVertical legH1 carryHitch WLL80%Carrying legLoad or heightSpare legLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Tension per carrying leg
6,000 lbf
Sling angle load factor
1 ×
Hook-to-pickup headroom
7 ft
Estimated assembly WLL
7,500 lb
Estimated WLL used
80 %
Effective carrying legs
1
Choke-angle capacity multiplier
—

A vertical sling carries the full weight. Compare the straight-hitch rating with the load and check the available drop.

Tension per carrying leg 6,000 lbf · Sling angle load factor 1 ×

Leg tension

T = W / (n × sin θ)

Measure θ from horizontal. In a vertical or single choker hitch, use θ = 90°.

Hitch capacity

Basket WLL = 2 × WLL₀ × sin θ

Bridle WLL uses the effective leg count and the same sine factor. Apply the choke-angle multiplier to the tagged wire-rope choker WLL. With no tagged choker WLL, 0.75 × WLL₀ is illustrative.

Headroom

H = r × tan θ

r is the horizontal reach from the hook centerline to a pickup. At 90°, use the measured drop. A multi-leg 90° case assumes parallel legs with matching upper supports.

Compare with the tagged assembly WLL for the actual material, hitch, angle, number of legs, fittings and bend radius. Use the lower approved limit. Have a qualified person verify load sharing and the assumptions for rigid loads.