ASME B30.5 · OSHA 1926.1402

Soft-clay bearing screen for one outrigger

A 190 kN peak jack reaction is applied to a square mat over soil tentatively described as soft clay.

Inputs

Peak reaction
kN
Pad and ground
m
mm
mm
Back to results ↑

Results

Static screeningEdit inputs ↓
Outrigger and mat sectionPEAK REACTION190kNGROUND PRESS74.22kPaBEARING AREA2.56m²SOIL USE148.44%JACK REACTION45° spreadMatSoilEffective contactSoil bearing limit148.44%Applied reactionMat load spreadGround contactLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • Estimated bearing pressure exceeds the selected allowable pressure.
  • Illustrative soil value selected. Obtain the allowable bearing pressure for this location.
  • The 45° spread reaches only part of the pad footprint in this model.
Peak reaction at one pad
190 kN
Effective ground pressure
74.22 kPa
Effective bearing area
2.56 m²
Allowable pressure used
148.44 %
Effective pressure in psi
10.76 psi
Full-footprint pressure
32.99 kPa
Effective width or diameter
1.6 m
Area needed at entered limit
3.8 m²
Entered allowable pressure
50 kPa

The illustrative clay value is only a comparison. Obtain site evidence for bearing and settlement before specifying the mat.

Peak reaction at one pad 190 kN · Effective ground pressure 74.22 kPa

Peak corner reaction

R = (Wcrane + Wload + Wrigging) × f

Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.

Effective contact

Dₑ = min(Dpad, Dfoot + 2t)

Assume centered load and a 45° spread through the mat thickness t. Apply the limit on each rectangular axis. For round pads use πDₑ²/4.

Bearing pressure

p = R / Aₑ

Compare with the site-specific allowable pressure. Full-pad pressure is a reference and assumes complete load distribution.

Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.