ASME B30.20 · ASME BTH-1

Spreader versus lifting beam under a low roof

A 19,000 lb machine has end pickups spaced 16 ft apart. The spreader uses 45° top slings and the center-picked beam needs 18 in of rise.

Inputs

Load and geometry
lb
ft
°
ft
lbf·ft
Spreader pipe properties
in
in
Msi
ksi
×
×
Back to results ↑

Results

Static screeningEdit inputs ↓
Spreader and lifting beam free bodiesCOMPRESSION9,500lbfBEAM MOMENT76,000lbf·ftEULER LOAD218,558lbfHEIGHT SAVED6.5ftSPREADER BARLIFTING BEAMAXIAL COMPRESSIONCENTER BENDINGSpreader axial limit20.75%Beam moment limit84.44%Sling tensionMember reactionReference or heightLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Spreader axial compression
9,500 lbf
Lifting beam peak bending
76,000 lbf·ft
Ideal Euler buckling load
218,557.65 lbf
Headroom saved with beam
6.5 ft
Pipe slenderness, KL/r
85.51
E3 axial load at screening factor
45,784.96 lbf
Tension per upper sling
13,435.03 lbf
Spreader hook rise above pickup
8 ft

Compare headroom at matching pickup elevations. The arrangement that fits may need the larger bending capacity.

Spreader axial compression 9,500 lbf · Lifting beam peak bending 76,000 lbf·ft

Spreader force

C = (W/2) / tan θ

Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).

Pipe buckling

Pₑ = π²EI / (KL)²

The AISC E3 flexural column curve reduces elastic or inelastic strength for a non-slender round steel section. Divide its nominal strength by the entered screening factor.

Beam comparison

M = WL/4; ΔH = (L/2) tan θ − Hbeam

Assume symmetrical end forces and a single center pick. Compare equal reference points for headroom.

Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.