ASME B30.5 · OSHA 1926.1402

Thin pad on a dense-gravel example

A 180 kN corner reaction reaches an 1.8 m pad through a jack foot only 0.5 m wide and a 100 mm pad.

Inputs

Peak reaction
kN
Pad and ground
m
mm
mm
Back to results ↑

Results

Static screeningEdit inputs ↓
Outrigger and mat sectionPEAK REACTION180kNGROUND PRESS367.35kPaBEARING AREA0.49m²SOIL USE183.67%JACK REACTION45° spreadMatSoilEffective contactSoil bearing limit183.67%Applied reactionMat load spreadGround contactLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • Estimated bearing pressure exceeds the selected allowable pressure.
  • Illustrative soil value selected. Obtain the allowable bearing pressure for this location.
  • The 45° spread reaches only part of the pad footprint in this model.
Peak reaction at one pad
180 kN
Effective ground pressure
367.35 kPa
Effective bearing area
0.49 m²
Allowable pressure used
183.67 %
Effective pressure in psi
53.28 psi
Full-footprint pressure
55.56 kPa
Effective width or diameter
0.7 m
Area needed at entered limit
0.9 m²
Entered allowable pressure
200 kPa

The modeled distribution reaches a much smaller area than the pad outline. Compare pressure before giving credit for a wider footprint.

Peak reaction at one pad 180 kN · Effective ground pressure 367.35 kPa

Peak corner reaction

R = (Wcrane + Wload + Wrigging) × f

Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.

Effective contact

Dₑ = min(Dpad, Dfoot + 2t)

Assume centered load and a 45° spread through the mat thickness t. Apply the limit on each rectangular axis. For round pads use πDₑ²/4.

Bearing pressure

p = R / Aₑ

Compare with the site-specific allowable pressure. Full-pad pressure is a reference and assumes complete load distribution.

Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.