Peak corner reaction
R = (Wcrane + Wload + Wrigging) × f
Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.
ASME B30.5 · OSHA 1926.1402
A 180 kN corner reaction reaches an 1.8 m pad through a jack foot only 0.5 m wide and a 100 mm pad.
Schematic geometry. Margin bars mark 100% of the entered limit.
The modeled distribution reaches a much smaller area than the pad outline. Compare pressure before giving credit for a wider footprint.
Peak reaction at one pad 180 kN · Effective ground pressure 367.35 kPa
R = (Wcrane + Wload + Wrigging) × f
Enter the highest OEM reaction over the full lift path when available. The corner-share option is a provisional estimate.
Dₑ = min(Dpad, Dfoot + 2t)
Assume centered load and a 45° spread through the mat thickness t. Apply the limit on each rectangular axis. For round pads use πDₑ²/4.
p = R / Aₑ
Compare with the site-specific allowable pressure. Full-pad pressure is a reference and assumes complete load distribution.
Use a verified geotechnical bearing value and OEM outrigger reactions. Have pad or mat strength, effective bearing, settlement, slope, underground services and voids checked separately.