Solve a four-component vapor–liquid split and size a vertical drum from gas load and liquid surge.
Equal moles of a light and heavy component enter a flash with K-values of 2 and 0.5.
- Vapor V/F
- 50 %
- Drum ID
- 0.7536 m
- T/T height
- 2.261 m
- Mass error
- 0 %
Vertical flash drum and mist eliminator
Live schematicScreen against the gas velocity limit and a liquid surge depth of one shell diameter.
Calculation inputs
- z1 feed
- 0.5
- K1
- 2
- MW1
- 44.1 kg/kmol
- z2 feed
- 0.5
- K2
- 0.5
- MW2
- 58.12 kg/kmol
- z3 feed
- 0
- K3
- 0.23
- MW3
- 72.15 kg/kmol
- z4 feed
- 0
- K4
- 0.1
- MW4
- 86.18 kg/kmol
- Feed basis
- Mass flow
- Feed mass flow F
- 5,400 kg/h
- Liquid density ρL
- 700 kg/m³
- Vapor density ρV
- 6.2 kg/m³
- Demister K-factor
- 0.105 m/s
- Gas design fraction
- 80 %
- Liquid surge time
- 5 min
- Check shell ID
- 0 m
Worked solution
- Establish the phase state
Normalize the feed. Σ zK = 1.25 and Σ z/K = 1.25. The equilibrium result is two phase at V/F = 50 %.
- Close the phase balances
The phase compositions and component molecular weights give 2,577 kg/h vapor and 2,823 kg/h liquid. The relative mass imbalance is 0 %.
- Size the drum
The gas-area ID is 0.4067 m and the surge ID is 0.7536 m. At the checked ID, two diameters plus surge depth give a T/T height of 2.261 m.
The Rachford–Rice root is 0.5. Phase mass fractions differ from mole fractions because molecular weights differ. The derivation uses SI units.
| Component | Feed z | Liquid x | Vapor y |
|---|---|---|---|
| 1 | 0.5 | 0.33333 | 0.66667 |
| 2 | 0.5 | 0.66667 | 0.33333 |
| 3 | 0 | 0 | 0 |
| 4 | 0 | 0 | 0 |
| Phase state | Two phase |
|---|---|
| Mixed feed molecular weight | 51.11 kg/kmol |
| Feed molar flow | 105.7 kmol/h |
| Feed mass flow | 5,400 kg/h |
| Vapor mass flow | 2,577 kg/h |
| Liquid mass flow | 2,823 kg/h |
| Actual vapor flow | 415.6 Am³/h |
| Liquid flow | 4.034 m³/h |
| Gas velocity limit | 1.111 m/s |
| Liquid surge volume | 0.3361 m³ |
| Required drum ID | 0.7536 m |
| Liquid surge depth | 0.7536 m |
| Gas velocity approach | 23.3 % |
| Surge-depth approach | 100 % |
Calculation inputs
Live updates
Equations and assumptions
- Phase endpoints
- Σ zᵢKᵢ ≤ 1 → liquid · Σ zᵢ/Kᵢ ≤ 1 → vapor
- Two-phase split
- Σ zᵢ(Kᵢ − 1) / [1 + β(Kᵢ − 1)] = 0
- Composition
- xᵢ = zᵢ/[1 + β(Kᵢ − 1)] · yᵢ = Kᵢxᵢ
- Drum height
- HT/T = 2D + Vsurge / (πD²/4)
K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.
The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.