Worked example · Flash equilibrium
Flash drum with limited surge shell
Solve a four-component vapor–liquid split and size a vertical drum from gas load and liquid surge.
Check a 0.48 m ID vertical drum at a five-minute surge requirement.
- Vapor V/F
- 62.66 %
- Drum ID
- 0.48 m
- T/T height
- 2.421 m
- Mass error
- 0 %
Vertical flash drum and mist eliminator
Live schematicGas loading or surge depth exceeds the modeled limit for this shell.
Calculation inputs
- z1 feed
- 0.52
- K1
- 2.4
- MW1
- 44.1 kg/kmol
- z2 feed
- 0.33
- K2
- 0.62
- MW2
- 58.12 kg/kmol
- z3 feed
- 0.15
- K3
- 0.23
- MW3
- 72.15 kg/kmol
- z4 feed
- 0
- K4
- 0.1
- MW4
- 86.18 kg/kmol
- Feed basis
- Mass flow
- Feed mass flow F
- 5,400 kg/h
- Liquid density ρL
- 700 kg/m³
- Vapor density ρV
- 6.2 kg/m³
- Demister K-factor
- 0.105 m/s
- Gas design fraction
- 80 %
- Liquid surge time
- 5 min
- Check shell ID
- 0.48 m
Worked solution
- Establish the phase state
Normalize the feed. Σ zK = 1.4871 and Σ z/K = 1.4011. The equilibrium result is two phase at V/F = 62.66 %.
- Close the phase balances
The phase compositions and component molecular weights give 3,179 kg/h vapor and 2,221 kg/h liquid. The relative mass imbalance is 0 %.
- Size the drum
The gas-area ID is 0.4518 m and the surge ID is 0.6956 m. At the checked ID, two diameters plus surge depth give a T/T height of 2.421 m.
Compare the gas velocity approach and the surge-depth approach in the same drum. The derivation uses SI units.
| Component | Feed z | Liquid x | Vapor y |
|---|---|---|---|
| 1 | 0.52 | 0.27699 | 0.66478 |
| 2 | 0.33 | 0.43314 | 0.26855 |
| 3 | 0.15 | 0.28986 | 0.066669 |
| 4 | 0 | 0 | 0 |
| Phase state | Two phase |
|---|---|
| Mixed feed molecular weight | 52.93 kg/kmol |
| Feed molar flow | 102 kmol/h |
| Feed mass flow | 5,400 kg/h |
| Vapor mass flow | 3,179 kg/h |
| Liquid mass flow | 2,221 kg/h |
| Actual vapor flow | 512.8 Am³/h |
| Liquid flow | 3.172 m³/h |
| Gas velocity limit | 1.111 m/s |
| Liquid surge volume | 0.2644 m³ |
| Required drum ID | 0.6956 m |
| Liquid surge depth | 1.461 m |
| Gas velocity approach | 70.87 % |
| Surge-depth approach | 304.4 % |
Calculation inputs
Live updates
Equations and assumptions
- Phase endpoints
- Σ zᵢKᵢ ≤ 1 → liquid · Σ zᵢ/Kᵢ ≤ 1 → vapor
- Two-phase split
- Σ zᵢ(Kᵢ − 1) / [1 + β(Kᵢ − 1)] = 0
- Composition
- xᵢ = zᵢ/[1 + β(Kᵢ − 1)] · yᵢ = Kᵢxᵢ
- Drum height
- HT/T = 2D + Vsurge / (πD²/4)
K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.
The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.