DistillColumnLab
Menu

Worked example · Flash equilibrium

At the flash dew endpoint

Solve a four-component vapor–liquid split and size a vertical drum from gas load and liquid surge.

A 25:75 feed with K-values 0.5 and 1.5 has Σ z/K = 1.

Vapor V/F
100 %
Drum ID
0.5888 m
T/T height
1.178 m
Mass error
0 %

Vertical flash drum and mist eliminator

Live schematic
Flash drum with demister, vapor outlet and liquid surge regionFLASH FEED5,400 kg/hVAPOR SHARE100 %VAPOR871 Am³/hMIST PADT/T HEIGHT1.18 mLIQUID SURGE0 m³ID 0.589 m
Vapor only

Screen against the gas velocity limit and a liquid surge depth of one shell diameter.

Highest gas velocity or surge-depth approach80 %
Review marker 85 % Screen limit 100 %

Worked solution

  1. Establish the phase state

    Normalize the feed. Σ zK = 1.25 and Σ z/K = 1. The equilibrium result is vapor only at V/F = 100 %.

  2. Close the phase balances

    The phase compositions and component molecular weights give 5,400 kg/h vapor and 0 kg/h liquid. The relative mass imbalance is 0 %.

  3. Size the drum

    The gas-area ID is 0.5888 m and the surge ID is 0 m. At the checked ID, two diameters plus surge depth give a T/T height of 1.178 m.

The bulk feed is vapor. The gas area sets the minimum drum size. The derivation uses SI units.

Phase mole fractions
ComponentFeed zLiquid xVapor y
10.25—0.25
20.75—0.75
30—0
40—0
Calculation details
Phase stateVapor only
Mixed feed molecular weight54.61 kg/kmol
Feed molar flow98.88 kmol/h
Feed mass flow5,400 kg/h
Vapor mass flow5,400 kg/h
Liquid mass flow0 kg/h
Actual vapor flow871 Am³/h
Liquid flow0 m³/h
Gas velocity limit1.111 m/s
Liquid surge volume0 m³
Required drum ID0.5888 m
Liquid surge depth0 m
Gas velocity approach80 %
Surge-depth approach0 %

Calculation inputs

Live updates

Feed mixture

Feed entries are normalized. Use z = 0 for an unused component.

kg/kmol
kg/kmol
kg/kmol
kg/kmol
Throughput
kg/h
kg/m³
kg/m³
Vessel screening
m/s
%
min
m
0 uses the calculated size
Back to results

Equations and assumptions

Phase endpoints
Σ zᵢKᵢ ≤ 1 → liquid · Σ zᵢ/Kᵢ ≤ 1 → vapor
Two-phase split
Σ zᵢ(Kᵢ − 1) / [1 + β(Kᵢ − 1)] = 0
Composition
xᵢ = zᵢ/[1 + β(Kᵢ − 1)] · yᵢ = Kᵢxᵢ
Drum height
HT/T = 2D + Vsurge / (πD²/4)

K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.

The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.

Method references