DistillColumnLab
Menu

Worked example · Gas thermodynamics

Subcritical carbon dioxide roots

Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.

Carbon dioxide at 5 °C and 30 bar absolute lies below its critical temperature.

Z factor
0.76314
Gas density
74.81 kg/m³
Actual flow
8.46 Am³/h
Standard flow
320 Nm³/h

Vapor-branch compressibility isotherm

Live schematic
Compressibility versus absolute pressure along the selected isotherm09001,8002,7003,6000.67580.76290.84990.9371.024COMPRESSIBILITY ZPRESSURE kPa absISOTHERM5 °COPERATING Z0.76314ADMISSIBLE ROOTS3EOS vapor rootIdeal gasOperating point
Subcritical EOS root

Confirm phase stability with vapor-pressure or mixture data before using vapor-branch results.

Absolute compressibility departure |Z − 1|23.7 %
Review marker 5 % Screen limit 10 %

Worked solution

  1. Solve both EOS states

    At the operating pressure of 3,000 kPa abs, the largest admissible root is 0.7631424. At the reference state it is 0.992788.

  2. Get densities and conserve mass

    Evaluate P MW/(ZRT) at both states for 74.81 kg/m³ actual and 1.978 kg/m³ reference. The stream carries 632.9 kg/h.

  3. Convert volumetric flow

    Divide that mass flow by the density at each state. The result is 8.46 Am³/h actual and 320 Nm³/h standard.

The largest admissible root is selected when there are several real roots. Phase stability needs separate confirmation. The derivation uses SI units.

Calculation details
Mass flow632.9 kg/h
Reference compressibility0.992788
Reference density1.978 kg/m³
Operating reduced temperature0.9146
Operating reduced pressure0.4067
Operating EOS coefficient A0.2362
Operating EOS coefficient B0.03459
Scaled cubic residual7.619e-18

Admissible roots 0.06733001 · 0.1349352 · 0.7631424

Calculation inputs

Live updates

Gas and equation
kg/kmol
°C
bar abs
Operating and reference states
°C
kPa abs
°C
kPa abs
Volume flow

Both unit systems use the reference state shown above.

Nm³/h
Back to results

Equations and assumptions

Peng–Robinson cubic
Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
Redlich–Kwong cubic
Z³ − Z² + (A−B−B²)Z − AB = 0
Gas density
ρ = P MW / (Z R T)
Volume conversion
Qs ρs = Qa ρa

A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.

The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.

Method references