Worked example · Gas thermodynamics
Subcritical carbon dioxide roots
Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.
Carbon dioxide at 5 °C and 30 bar absolute lies below its critical temperature.
- Z factor
- 0.76314
- Gas density
- 74.81 kg/m³
- Actual flow
- 8.46 Am³/h
- Standard flow
- 320 Nm³/h
Vapor-branch compressibility isotherm
Live schematicConfirm phase stability with vapor-pressure or mixture data before using vapor-branch results.
Calculation inputs
- Gas preset
- Carbon dioxide
- Equation of state
- Peng–Robinson
- Molecular weight MW
- 44.01 kg/kmol
- Critical temperature Tc
- 30.98 °C
- Critical pressure Pc
- 73.77 bar abs
- Acentric factor ω
- 0.2239
- Operating temperature
- 5 °C
- Operating pressure
- 3,000 kPa abs
- Reference temperature
- 0 °C
- Reference pressure
- 101.3 kPa abs
- Entered flow basis
- Standard volume
- Entered volume flow
- 320 Nm³/h
Worked solution
- Solve both EOS states
At the operating pressure of 3,000 kPa abs, the largest admissible root is 0.7631424. At the reference state it is 0.992788.
- Get densities and conserve mass
Evaluate P MW/(ZRT) at both states for 74.81 kg/m³ actual and 1.978 kg/m³ reference. The stream carries 632.9 kg/h.
- Convert volumetric flow
Divide that mass flow by the density at each state. The result is 8.46 Am³/h actual and 320 Nm³/h standard.
The largest admissible root is selected when there are several real roots. Phase stability needs separate confirmation. The derivation uses SI units.
| Mass flow | 632.9 kg/h |
|---|---|
| Reference compressibility | 0.992788 |
| Reference density | 1.978 kg/m³ |
| Operating reduced temperature | 0.9146 |
| Operating reduced pressure | 0.4067 |
| Operating EOS coefficient A | 0.2362 |
| Operating EOS coefficient B | 0.03459 |
| Scaled cubic residual | 7.619e-18 |
Admissible roots 0.06733001 · 0.1349352 · 0.7631424
Calculation inputs
Live updates
Equations and assumptions
- Peng–Robinson cubic
- Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
- Redlich–Kwong cubic
- Z³ − Z² + (A−B−B²)Z − AB = 0
- Gas density
- ρ = P MW / (Z R T)
- Volume conversion
- Qs ρs = Qa ρa
A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.
The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.