Worked example · Liquid–liquid separation
Residence-limited decanter
Size a horizontal decanter or API-style bay from droplet rise or settling, residence time and seal-leg head.
A horizontal decanter requires a 48-minute continuous-phase residence time.
- Droplet speed
- 3.209 mm/s
- Droplet Re
- 0.5818
- Overflow area
- 2.077 m²
- Seal crest
- 1.815 m
Oil–water interface and heavy-phase seal leg
Live schematicDroplet Reynolds number is at or below 1 under the entered continuous-phase conditions.
Calculation inputs
- Continuous phase ρc
- 997 kg/m³
- Dispersed phase ρd
- 835 kg/m³
- Continuous viscosity μc
- 1.1 mPa·s
- Droplet diameter dp
- 200 µm
- Continuous volume flow
- 24 m³/h
- Separator geometry
- Circular horizontal decanter
- Residence time target
- 48 min
- Length / width or bore
- 3.2
- Interface / liquid depth
- 62 %
- Liquid depth / width
- 76 %
Worked solution
- Check the droplet regime
Stokes gives 3.209 mm/s at Re = 0.5818. The ideal projected overflow area is 2.077 m².
- Size for overflow and hold-up
Use the chosen geometry, a separation area of 2.077 m² and the continuous-phase residence target. Size to 8.145 m × 2.545 m at 48 min of hold-up.
- Balance the liquid heads
At liquid level 1.934 m and interface 1.199 m, the heavy-phase seal crest is 1.815 m above the bottom.
Longer residence can govern diameter even after the projected overflow area is sufficient. The derivation uses SI units.
| Design separation area | 2.077 m² |
|---|---|
| Sized separation area | 20.69 m² |
| Separator length | 8.145 m |
| Bay width or vessel bore | 2.545 m |
| Total operating liquid depth | 1.934 m |
| Liquid interface elevation | 1.199 m |
| Continuous-phase hold-up | 19.2 m³ |
| Continuous-phase residence time | 48 min |
| Bulk horizontal velocity | 0.002828 m/s |
| API-style horizontal velocity cap | — m/s |
| Short-circuit / turbulence factor | 1 |
Calculation inputs
Live updates
Equations and assumptions
- Stokes velocity
- vt = g dp² |ρc − ρd| / (18 μc)
- Regime check
- Rep = ρc vt dp / μc
- Ideal overflow area
- Ah = Qc / vt
- Seal-leg crest
- z = hi + (ρlight/ρheavy)(H − hi)
The circular decanter uses the interfacial chord in the separation area and a circular segment for continuous-phase hold-up. The rectangular bay sizes for corrected overflow area, residence time and a bulk horizontal velocity at most the lesser of 15 vt and 3 ft/min.
The API-style sizing includes an interpolated turbulence and short-circuit factor at the allowed velocity. It checks representative geometry criteria for oil rising in water. The Stokes model assumes dilute spherical droplets and is screened at Rep ≤ 1.
The seal-leg crest is measured from the vessel bottom at equal gas pressure on the two sides. Dynamic head losses, nozzle allowances and emulsions require separate evaluation.