Residence-limited decanter

Size a horizontal decanter or API-style bay from droplet rise or settling, residence time and seal-leg head.

A horizontal decanter requires a 48-minute continuous-phase residence time.

Droplet speed
3.209 mm/s
Droplet Re
0.5818
Overflow area
2.077 m²
Seal crest
1.815 m

Oil–water interface and heavy-phase seal leg

Live schematic
Horizontal decanter showing light and heavy layers with hydrostatic seal legOIL DROPLETS RISE3.21 mm/sINTERFACE1.2 mSEAL CREST1.81 m8.14 m × 2.55 mLight liquidHeavy liquidVessel datum
Within Stokes screen

Droplet Reynolds number is at or below 1 under the entered continuous-phase conditions.

Droplet Reynolds number vs Stokes limit0.582
Review marker 1 Screen limit 1

Worked solution

  1. Check the droplet regime

    Stokes gives 3.209 mm/s at Re = 0.5818. The ideal projected overflow area is 2.077 m².

  2. Size for overflow and hold-up

    Use the chosen geometry, a separation area of 2.077 m² and the continuous-phase residence target. Size to 8.145 m × 2.545 m at 48 min of hold-up.

  3. Balance the liquid heads

    At liquid level 1.934 m and interface 1.199 m, the heavy-phase seal crest is 1.815 m above the bottom.

Longer residence can govern diameter even after the projected overflow area is sufficient. The derivation uses SI units.

Calculation details
Design separation area2.077 m²
Sized separation area20.69 m²
Separator length8.145 m
Bay width or vessel bore2.545 m
Total operating liquid depth1.934 m
Liquid interface elevation1.199 m
Continuous-phase hold-up19.2 m³
Continuous-phase residence time48 min
Bulk horizontal velocity0.002828 m/s
API-style horizontal velocity cap— m/s
Short-circuit / turbulence factor1

Calculation inputs

Live updates

Phases and throughput
kg/m³
kg/m³
mPa·s
µm
m³/h
Vessel and interface
min
%
%
Back to results

Equations and assumptions

Stokes velocity
vt = g dp² |ρc − ρd| / (18 μc)
Regime check
Rep = ρc vt dp / μc
Ideal overflow area
Ah = Qc / vt
Seal-leg crest
z = hi + (ρlight/ρheavy)(H − hi)

The circular decanter uses the interfacial chord in the separation area and a circular segment for continuous-phase hold-up. The rectangular bay sizes for corrected overflow area, residence time and a bulk horizontal velocity at most the lesser of 15 vt and 3 ft/min.

The API-style sizing includes an interpolated turbulence and short-circuit factor at the allowed velocity. It checks representative geometry criteria for oil rising in water. The Stokes model assumes dilute spherical droplets and is screened at Rep ≤ 1.

The seal-leg crest is measured from the vessel bottom at equal gas pressure on the two sides. Dynamic head losses, nozzle allowances and emulsions require separate evaluation.

Method references