A pressurized column carries 2,400 actual m³/h at a vapor density of 22 kg/m³.

Flood speed
0.3947 m/s
Required ID
1.767 m
% flood
82 %
Net area
2.06 m²

Crossflow tray and downcomer

Live schematic
Crossflow column trays with vapor risers and downcomersVAPOR FEED2,400 Am³/hFLOOD SPEED0.395 m/sTRAY SPACING750 mmDOWNCOMER16 %CHECKED ID1.77 mLiquid crossflowVapor riseTray deck
Within upper flood band

Review hydraulic margins at the maximum expected load.

Operating vapor velocity ÷ predicted flood82 %
Review marker 80 % Screen limit 100 %

Worked solution

  1. Correct the Fair capacity

    The flow parameter is 0.2392. The reference factor 0.08814 m/s becomes 0.07387 m/s after tension and system corrections.

  2. Convert vapor load to area

    The density term gives Uf = 0.3947 m/s. Divide the vapor flow in m³/s by Uf and the target fraction. The net area is 2.06 m² and the total area is 2.452 m².

  3. Check the shell

    The required ID is 1.767 m. At the checked ID of 1.767 m, the flood approach is 82 % with 3 pp to the 85% marker.

The density contrast and liquid load change both the Fair parameter and the flood velocity. The derivation uses SI units.

Calculation details
Fair flow parameter FLV0.2392
Fair capacity factor at reference tension0.08814 m/s
Corrected capacity factor Csb0.07387 m/s
Required total shell area2.452 m²
Checked shell ID1.767 m
Checked net vapor area2.06 m²
Checked downcomer area0.3924 m²
Operating net vapor velocity0.3236 m/s
Margin to 80% flood-2 pp
Margin to 85% flood3 pp

Calculation inputs

Live updates

Fluid properties
kg/m³
kg/m³
mN/m
Tray and shell
mm
0 < SF ≤ 1
%
Am³/h
%
m
0 uses the target size
Back to results

Equations and assumptions

Fair chart fit
FLV = (L/V)√(ρV/ρL)
Corrected capacity
Csb = C20 · (σ/20)^0.2 · SF
Flood velocity
Uf = Csb √[(ρL − ρV)/ρV]
Area basis
At = Qv / [Uf · target · (1 − Ad/At)]

The Lygeros–Magoulas fit to Fair data uses tray spacing in meters and the reference surface tension of 20 mN/m. Apply the system factor to account for foaming or service derating.

The meter marks 80% of predicted jet flood. The 80–85% operating band is a screening range. Downcomer area is reserved in the net-area calculation. Detailed backup, froth height, weeping and entrainment need tray hardware data.