Low surface tension tray service

Size the net vapor area and shell diameter, then compare jet-flood approach at a candidate shell ID.

An organic service has a surface tension of 11 mN/m and a gas density of 7.1 kg/m³.

Flood speed
0.7269 m/s
Required ID
1.99 m
% flood
74 %
Net area
2.737 m²

Crossflow tray and downcomer

Live schematic
Crossflow column trays with vapor risers and downcomersVAPOR FEED5,300 Am³/hFLOOD SPEED0.727 m/sTRAY SPACING600 mmDOWNCOMER12 %CHECKED ID1.99 mLiquid crossflowVapor riseTray deck
Below flood screening band

Velocity is below the screening threshold at the entered load.

Operating vapor velocity ÷ predicted flood74 %
Review marker 80 % Screen limit 100 %

Worked solution

  1. Correct the Fair capacity

    The flow parameter is 0.11. The reference factor 0.09148 m/s becomes 0.07305 m/s after tension and system corrections.

  2. Convert vapor load to area

    The density term gives Uf = 0.7269 m/s. Divide the vapor flow in m³/s by Uf and the target fraction. The net area is 2.737 m² and the total area is 3.11 m².

  3. Check the shell

    The required ID is 1.99 m. At the checked ID of 1.99 m, the flood approach is 74 % with 11 pp to the 85% marker.

Correct the Fair capacity for both surface tension and the density contrast. The derivation uses SI units.

Calculation details
Fair flow parameter FLV0.11
Fair capacity factor at reference tension0.09148 m/s
Corrected capacity factor Csb0.07305 m/s
Required total shell area3.11 m²
Checked shell ID1.99 m
Checked net vapor area2.737 m²
Checked downcomer area0.3732 m²
Operating net vapor velocity0.5379 m/s
Margin to 80% flood6 pp
Margin to 85% flood11 pp

Calculation inputs

Live updates

Fluid properties
kg/m³
kg/m³
mN/m
Tray and shell
mm
0 < SF ≤ 1
%
Am³/h
%
m
0 uses the target size
Back to results

Equations and assumptions

Fair chart fit
FLV = (L/V)√(ρV/ρL)
Corrected capacity
Csb = C20 · (σ/20)^0.2 · SF
Flood velocity
Uf = Csb √[(ρL − ρV)/ρV]
Area basis
At = Qv / [Uf · target · (1 − Ad/At)]

The Lygeros–Magoulas fit to Fair data uses tray spacing in meters and the reference surface tension of 20 mN/m. Apply the system factor to account for foaming or service derating.

The meter marks 80% of predicted jet flood. The 80–85% operating band is a screening range. Downcomer area is reserved in the net-area calculation. Detailed backup, froth height, weeping and entrainment need tray hardware data.

Method references