Worked example · Tray hydraulics

Foaming-service derating

Size the net vapor area and shell diameter, then compare jet-flood approach at a candidate shell ID.

A foaming service uses a 0.68 system factor at the same tray spacing and density basis.

Flood speed
0.8949 m/s
Required ID
2.191 m
% flood
73 %
Net area
3.317 m²

Crossflow tray and downcomer

Live schematic
Crossflow column trays with vapor risers and downcomersVAPOR FEED7,800 Am³/hFLOOD SPEED0.895 m/sTRAY SPACING600 mmDOWNCOMER12 %CHECKED ID2.19 mLiquid crossflowVapor riseTray deck
Below flood screening band

Velocity is below the screening threshold at the entered load.

Operating vapor velocity ÷ predicted flood73 %
Review marker 80 % Screen limit 100 %

Worked solution

  1. Correct the Fair capacity

    The flow parameter is 0.06562. The reference factor 0.09826 m/s becomes 0.06543 m/s after tension and system corrections.

  2. Convert vapor load to area

    The density term gives Uf = 0.8949 m/s. Divide the vapor flow in m³/s by Uf and the target fraction. The net area is 3.317 m² and the total area is 3.769 m².

  3. Check the shell

    The required ID is 2.191 m. At the checked ID of 2.191 m, the flood approach is 73 % with 12 pp to the 85% marker.

The system factor multiplies Fair capacity before the area calculation. The derivation uses SI units.

Calculation details
Fair flow parameter FLV0.06562
Fair capacity factor at reference tension0.09826 m/s
Corrected capacity factor Csb0.06543 m/s
Required total shell area3.769 m²
Checked shell ID2.191 m
Checked net vapor area3.317 m²
Checked downcomer area0.4523 m²
Operating net vapor velocity0.6533 m/s
Margin to 80% flood7 pp
Margin to 85% flood12 pp

Calculation inputs

Live updates

Fluid properties
kg/m³
kg/m³
mN/m
Tray and shell
mm
0 < SF ≤ 1
%
Am³/h
%
m
0 uses the target size
Back to results

Equations and assumptions

Fair chart fit
FLV = (L/V)√(ρV/ρL)
Corrected capacity
Csb = C20 · (σ/20)^0.2 · SF
Flood velocity
Uf = Csb √[(ρL − ρV)/ρV]
Area basis
At = Qv / [Uf · target · (1 − Ad/At)]

The Lygeros–Magoulas fit to Fair data uses tray spacing in meters and the reference surface tension of 20 mN/m. Apply the system factor to account for foaming or service derating.

The meter marks 80% of predicted jet flood. The 80–85% operating band is a screening range. Downcomer area is reserved in the net-area calculation. Detailed backup, froth height, weeping and entrainment need tray hardware data.

Method references