DistillColumnLab
Menu

Worked example · Gas thermodynamics

Dry air near atmospheric pressure

Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.

A dry-air vent operates at 1.08 bar absolute and 21 °C on an actual-volume basis.

Z factor
0.99935
Gas density
1.28 kg/m³
Actual flow
460 Am³/h
Standard flow
455.2 Nm³/h

Vapor-branch compressibility isotherm

Live schematic
Compressibility versus absolute pressure along the selected isotherm032.464.897.21300.98720.99340.99961.0061.012COMPRESSIBILITY ZPRESSURE kPa absISOTHERM21 °COPERATING Z0.99935ADMISSIBLE ROOTS1EOS vapor rootIdeal gasOperating point
Near ideal-gas behavior

The 5% deviation marker compares the operating compressibility to Z = 1.

Absolute compressibility departure |Z − 1|0.0654 %
Review marker 5 % Screen limit 10 %

Worked solution

  1. Solve both EOS states

    At the operating pressure of 108 kPa abs, the largest admissible root is 0.9993457. At the reference state it is 0.9991036.

  2. Get densities and conserve mass

    Evaluate P MW/(ZRT) at both states for 1.28 kg/m³ actual and 1.293 kg/m³ reference. The stream carries 588.8 kg/h.

  3. Convert volumetric flow

    Divide that mass flow by the density at each state. The result is 460 Am³/h actual and 455.2 Nm³/h standard.

Z approaches 1 and the volume conversion mainly follows the difference in absolute pressure and temperature. The derivation uses SI units.

Calculation details
Mass flow588.8 kg/h
Reference compressibility0.999104
Reference density1.293 kg/m³
Operating reduced temperature2.219
Operating reduced pressure0.02853
Operating EOS coefficient A0.001658
Operating EOS coefficient B9.999e-4
Scaled cubic residual2.076e-17

Admissible roots 0.9993457

Calculation inputs

Live updates

Gas and equation
kg/kmol
°C
bar abs
Operating and reference states
°C
kPa abs
°C
kPa abs
Volume flow

Both unit systems use the reference state shown above.

Am³/h
Back to results

Equations and assumptions

Peng–Robinson cubic
Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
Redlich–Kwong cubic
Z³ − Z² + (A−B−B²)Z − AB = 0
Gas density
ρ = P MW / (Z R T)
Volume conversion
Qs ρs = Qa ρa

A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.

The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.

Method references