DistillColumnLab
Menu

Worked example · Flash equilibrium

Flash drum with limited surge shell

Solve a four-component vapor–liquid split and size a vertical drum from gas load and liquid surge.

Check a 0.48 m ID vertical drum at a five-minute surge requirement.

Vapor V/F
62.66 %
Drum ID
0.48 m
T/T height
2.421 m
Mass error
0 %

Vertical flash drum and mist eliminator

Live schematic
Flash drum with demister, vapor outlet and liquid surge regionFLASH FEED5,400 kg/hVAPOR SHARE62.7 %VAPOR513 Am³/hMIST PADT/T HEIGHT2.42 mLIQUID SURGE0.264 m³ID 0.48 m
Two phase

Gas loading or surge depth exceeds the modeled limit for this shell.

Highest gas velocity or surge-depth approach304 %
Review marker 85 % Screen limit 100 %

Worked solution

  1. Establish the phase state

    Normalize the feed. Σ zK = 1.4871 and Σ z/K = 1.4011. The equilibrium result is two phase at V/F = 62.66 %.

  2. Close the phase balances

    The phase compositions and component molecular weights give 3,179 kg/h vapor and 2,221 kg/h liquid. The relative mass imbalance is 0 %.

  3. Size the drum

    The gas-area ID is 0.4518 m and the surge ID is 0.6956 m. At the checked ID, two diameters plus surge depth give a T/T height of 2.421 m.

Compare the gas velocity approach and the surge-depth approach in the same drum. The derivation uses SI units.

Phase mole fractions
ComponentFeed zLiquid xVapor y
10.520.276990.66478
20.330.433140.26855
30.150.289860.066669
4000
Calculation details
Phase stateTwo phase
Mixed feed molecular weight52.93 kg/kmol
Feed molar flow102 kmol/h
Feed mass flow5,400 kg/h
Vapor mass flow3,179 kg/h
Liquid mass flow2,221 kg/h
Actual vapor flow512.8 Am³/h
Liquid flow3.172 m³/h
Gas velocity limit1.111 m/s
Liquid surge volume0.2644 m³
Required drum ID0.6956 m
Liquid surge depth1.461 m
Gas velocity approach70.87 %
Surge-depth approach304.4 %

Calculation inputs

Live updates

Feed mixture

Feed entries are normalized. Use z = 0 for an unused component.

kg/kmol
kg/kmol
kg/kmol
kg/kmol
Throughput
kg/h
kg/m³
kg/m³
Vessel screening
m/s
%
min
m
0 uses the calculated size
Back to results

Equations and assumptions

Phase endpoints
Σ zᵢKᵢ ≤ 1 → liquid · Σ zᵢ/Kᵢ ≤ 1 → vapor
Two-phase split
Σ zᵢ(Kᵢ − 1) / [1 + β(Kᵢ − 1)] = 0
Composition
xᵢ = zᵢ/[1 + β(Kᵢ − 1)] · yᵢ = Kᵢxᵢ
Drum height
HT/T = 2D + Vsurge / (πD²/4)

K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.

The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.

Method references