Natural gas at a standard flow rate

Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.

Convert a 1,600 standard m³/h stream of representative natural gas to actual flow at 45 °C and 64 bar absolute.

Z factor
0.87709
Gas density
49.65 kg/m³
Actual flow
25.97 Am³/h
Standard flow
1,600 Nm³/h

Vapor-branch compressibility isotherm

Live schematic
Compressibility versus absolute pressure along the selected isotherm01,9203,8405,7607,6800.84660.88790.92930.97061.012COMPRESSIBILITY ZPRESSURE kPa absISOTHERM45 °COPERATING Z0.87709ADMISSIBLE ROOTS1EOS vapor rootIdeal gasOperating point
Real-gas correction material

The 5% deviation marker compares the operating compressibility to Z = 1.

Absolute compressibility departure |Z − 1|12.3 %
Review marker 5 % Screen limit 10 %

Worked solution

  1. Solve both EOS states

    At the operating pressure of 6,400 kPa abs, the largest admissible root is 0.8770917. At the reference state it is 0.9963242.

  2. Get densities and conserve mass

    Evaluate P MW/(ZRT) at both states for 49.65 kg/m³ actual and 0.806 kg/m³ reference. The stream carries 1,290 kg/h.

  3. Convert volumetric flow

    Divide that mass flow by the density at each state. The result is 25.97 Am³/h actual and 1,600 Nm³/h standard.

The pseudo-pure gas basis gives an estimate. The mass flow is the same at standard and actual conditions. The derivation uses SI units.

Calculation details
Mass flow1,290 kg/h
Reference compressibility0.996324
Reference density0.806 kg/m³
Operating reduced temperature1.548
Operating reduced pressure1.391
Operating EOS coefficient A0.2119
Operating EOS coefficient B0.06992
Scaled cubic residual7.177e-18

Admissible roots 0.8770917

Calculation inputs

Live updates

Gas and equation
kg/kmol
°C
bar abs
Operating and reference states
°C
kPa abs
°C
kPa abs
Volume flow

Both unit systems use the reference state shown above.

Nm³/h
Back to results

Equations and assumptions

Peng–Robinson cubic
Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
Redlich–Kwong cubic
Z³ − Z² + (A−B−B²)Z − AB = 0
Gas density
ρ = P MW / (Z R T)
Volume conversion
Qs ρs = Qa ρa

A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.

The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.

Method references