Eckert · Strigle · Kremser
Packed-column diameter and height
Estimate GPDC flood capacity, then convert overall gas transfer units into packed height.
- Required ID
- 0.7901 m
- % flood
- 70 %
- Gas NTU
- 3.236
- Bed height
- 2.103 m
GPDC capacity curve and packed bed
Live schematicVelocity is below the screening threshold at the entered load.
Calculation inputs
- Liquid mass flow L
- 8,400 kg/h
- Gas mass flow G
- 5,500 kg/h
- Liquid density ρL
- 980 kg/m³
- Gas density ρV
- 2.3 kg/m³
- Liquid viscosity μL
- 1.05 mPa·s
- Packing preset
- 50 mm metal Pall ring
- Packing factor Fp
- 88.58 m⁻¹
- Flood correlation
- Strigle / Kister–Gill GPDC
- Design flood target
- 70 %
- Check shell ID
- 0 m
- Equilibrium slope m
- 1.1
- Carrier MW ratio MG/ML
- 1.25
- Inlet gas solute ratio yin
- 0.06
- Outlet gas solute ratio yout
- 0.009
- Inlet liquid solute ratio xin
- 0.0015
- Overall gas HTU
- 0.65 m
| Flow parameter FLV | 0.07399 |
|---|---|
| Flooding C-factor | 0.09388 m/s |
| Flood velocity | 1.936 m/s |
| Operating superficial velocity | 1.355 m/s |
| Checked shell ID | 0.7901 m |
| Operating gas flow | 2,391 Am³/h |
| Kister–Gill flood gradient (reference) | 944 Pa/m |
| Absorption factor A | 1.736 |
| Lean-end driving force | 0.00735 |
| Rich-end driving force | 0.02896 |
Calculation inputs
Live updates
Equations and assumptions
- Flow parameter
- FLV = (L/G)√(ρV/ρL)
- Modern flood curve
- ΔPfl = 0.115 Fp^0.7 · CP = Csf √Fp ν^0.05
- Terminal driving force
- Δrich = Δlean + (1 − 1/A)(yin − yout)
- Packed height
- Z = HTUOG · ln(Δrich/Δlean)/(1 − 1/A)
The Strigle choice evaluates the fitted random-packing GPDC at the Kister–Gill incipient-flood pressure drop in in H₂O/ft. The chart fit uses base-10 log FLV, kinematic liquid viscosity in cSt, and packing factor in ft⁻¹. The legacy Eckert option uses a direct flood-curve fit in natural log FLV with μL in Pa·s and Fp in ft⁻¹.
Prefilled packing factors are representative screening values. Structured packing uses the generalized curve with an explicit review flag. Use measured or vendor capacity data for that packing geometry, particularly above FLV of 0.3.
The Kremser-style transfer integral assumes constant solute-free molar flow and linear equilibrium. At A = 1 it becomes (yin − yout)/Δlean. For positive removal, both terminal driving forces must be positive.