Worked example

12S 5000 mAh LiPo high-current ESC & XT90 screen

Check 12S pack sag and ESC current at 80 A and see how the load compares with the illustrative XT90 screening range.

The 80 A case exceeds all three screening values even though the entered pack rating and ESC-channel averages are higher than the demand. Check tested component ratings.

Inputs

Battery & resistance

Enter effective resistance of a parallel group for an nS2P pack.

Load & ESC
View results

Example results

Estimated loaded pack voltage
43.62 V
Pack voltage sag
3.176 V
ESC headroom vs. rating
70.4 %
  • Current exceeds the illustrative continuous screening range. Check the exact connector, wire gauge, contacts and cooling.

Voltage under full-throttle load

Voltage under full-throttle loadOpen circuit is 46.8 volts. The estimated loaded pack voltage is 43.624 volts. The reference cutoff is 42 volts. Open-circuit voltage46.8 VEstimated loaded voltage43.624 VVoltage sag · 3.176 VPack cutoff · 42 V
Gold marks the entered cell cutoff multiplied by the number of series cells.
Pack continuous rating
125 A
Pack burst rating
175 A
Current per ESC
13.33 A
Average loaded cell voltage
3.635 V
Total modeled resistance
39.7 mΩ
Connector screening result
Above XT90 screen

Worked math

Equations use metric inputs unless a conventional unit is shown.

  1. Continuous and burst currents

    5 Ah × 25C / 35C = 125 A continuous / 175 A burst

  2. Pack and lead resistance

    12 × 3.1 mΩ + 2.5 mΩ = 39.7 mΩ

  3. Voltage under load

    46.8 V − (80 A × 0.0397 Ω) = 43.624 V

  4. ESC headroom

    80 A ÷ 6 = 13.333 A/ESC · (45 − 13.333) ÷ 45 = 70.37%

  5. Connector screen

    80 A exceeds the 45 A illustrative XT90 screen

Model assumptions

Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.

The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.

ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.

Frequently asked questions

Why does a pack within its C-rate limit exceed the XT90 screen?

The pack discharge rating and connector’s continuous thermal limit describe different parts of the current path. The minimum suitable rating depends on each component.

Can series count alone tell me 12S voltage sag?