12S 5000 mAh LiPo high-current ESC & XT90 screen
Check 12S pack sag and ESC current at 80 A and see how the load compares with the illustrative XT90 screening range.
The 80 A case exceeds all three screening values even though the entered pack rating and ESC-channel averages are higher than the demand. Check tested component ratings.
Example results
Check the highlighted inputs to calculate results.
- Estimated loaded pack voltage
- 43.62 V
- Pack voltage sag
- 3.176 V
- ESC headroom vs. rating
- 70.4 %
- Current exceeds the illustrative continuous screening range. Check the exact connector, wire gauge, contacts and cooling.
Voltage under full-throttle load
- Pack continuous rating
- 125 A
- Pack burst rating
- 175 A
- Current per ESC
- 13.33 A
- Average loaded cell voltage
- 3.635 V
- Total modeled resistance
- 39.7 mΩ
- Connector screening result
- Above XT90 screen
Scenario inputs
- Rated pack capacity
- 5,000 mAh
- Cells or parallel groups in series
- 12 S
- Starting open-circuit voltage per group
- 3.9 V
- Continuous discharge rating
- 25 C
- Burst discharge rating
- 35 C
- Resistance per series group
- 3.1 mΩ
- Total lead and connector resistance
- 2.5 mΩ
- Full-throttle pack draw
- 80 A
- Number of ESC channels
- 6
- Continuous current per ESC channel
- 45 A
- Loaded voltage floor per group
- 3.5 V
Worked math
Equations use metric inputs unless a conventional unit is shown.
- Continuous and burst currents
5 Ah × 25C / 35C = 125 A continuous / 175 A burst - Pack and lead resistance
12 × 3.1 mΩ + 2.5 mΩ = 39.7 mΩ - Voltage under load
46.8 V − (80 A × 0.0397 Ω) = 43.624 V - ESC headroom
80 A ÷ 6 = 13.333 A/ESC · (45 − 13.333) ÷ 45 = 70.37% - Connector screen
80 A exceeds the 45 A illustrative XT90 screen
Model assumptions
Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.
The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.
ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.
Frequently asked questions
Why does a pack within its C-rate limit exceed the XT90 screen?
The pack discharge rating and connector’s continuous thermal limit describe different parts of the current path. The minimum suitable rating depends on each component.
Can series count alone tell me 12S voltage sag?
Series count scales the modeled group resistance. Actual sag also depends on pack current, per-group resistance and shared wiring resistance.