6S2P 8400 mAh Li-ion pack sag & current draw
Estimate loaded voltage and discharge current on a 6S2P 8.4 Ah Li-ion pack using effective parallel-group resistance.
The example’s 10.5 mΩ is the effective resistance of each two-cell parallel group. Pack capacity and C-rating apply to the assembled pack.
Example results
Check the highlighted inputs to calculate results.
- Estimated loaded pack voltage
- 21.22 V
- Pack voltage sag
- 1.876 V
- ESC headroom vs. rating
- 72 %
Voltage under full-throttle load
- Pack continuous rating
- 33.6 A
- Pack burst rating
- 42 A
- Current per ESC
- 7 A
- Average loaded cell voltage
- 3.537 V
- Total modeled resistance
- 67 mΩ
- Connector screening result
- XT60
Scenario inputs
- Rated pack capacity
- 8,400 mAh
- Cells or parallel groups in series
- 6 S
- Starting open-circuit voltage per group
- 3.85 V
- Continuous discharge rating
- 4 C
- Burst discharge rating
- 5 C
- Resistance per series group
- 10.5 mΩ
- Total lead and connector resistance
- 4 mΩ
- Full-throttle pack draw
- 28 A
- Number of ESC channels
- 4
- Continuous current per ESC channel
- 25 A
- Loaded voltage floor per group
- 3.1 V
Worked math
Equations use metric inputs unless a conventional unit is shown.
- Continuous and burst currents
8.4 Ah × 4C / 5C = 33.6 A continuous / 42 A burst - Pack and lead resistance
6 × 10.5 mΩ + 4 mΩ = 67 mΩ - Voltage under load
23.1 V − (28 A × 0.067 Ω) = 21.224 V - ESC headroom
28 A ÷ 4 = 7 A/ESC · (25 − 7) ÷ 25 = 72% - Connector screen
28 A ≤ 30 A illustrative continuous screen for XT60
Model assumptions
Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.
The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.
ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.
Frequently asked questions
Does 6S2P mean I should enter 12 series cells?
Enter six series groups. Parallel cells increase capacity and share current within each group while leaving the group voltage unchanged.
How do I convert a group’s measured resistance from ohms to mΩ?
Multiply ohms by 1,000. For example, 0.0105 Ω is 10.5 mΩ per group.