Worked example

6S2P 8400 mAh Li-ion pack sag & current draw

Estimate loaded voltage and discharge current on a 6S2P 8.4 Ah Li-ion pack using effective parallel-group resistance.

The example’s 10.5 mΩ is the effective resistance of each two-cell parallel group. Pack capacity and C-rating apply to the assembled pack.

Inputs

Battery & resistance

Enter effective resistance of a parallel group for an nS2P pack.

Load & ESC
View results

Example results

Estimated loaded pack voltage
21.22 V
Pack voltage sag
1.876 V
ESC headroom vs. rating
72 %

Voltage under full-throttle load

Voltage under full-throttle loadOpen circuit is 23.1 volts. The estimated loaded pack voltage is 21.224 volts. The reference cutoff is 18.6 volts. Open-circuit voltage23.1 VEstimated loaded voltage21.224 VVoltage sag · 1.876 VPack cutoff · 18.6 V
Gold marks the entered cell cutoff multiplied by the number of series cells.
Pack continuous rating
33.6 A
Pack burst rating
42 A
Current per ESC
7 A
Average loaded cell voltage
3.537 V
Total modeled resistance
67 mΩ
Connector screening result
XT60

Worked math

Equations use metric inputs unless a conventional unit is shown.

  1. Continuous and burst currents

    8.4 Ah × 4C / 5C = 33.6 A continuous / 42 A burst

  2. Pack and lead resistance

    6 × 10.5 mΩ + 4 mΩ = 67 mΩ

  3. Voltage under load

    23.1 V − (28 A × 0.067 Ω) = 21.224 V

  4. ESC headroom

    28 A ÷ 4 = 7 A/ESC · (25 − 7) ÷ 25 = 72%

  5. Connector screen

    28 A ≤ 30 A illustrative continuous screen for XT60

Model assumptions

Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.

The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.

ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.

Frequently asked questions

Does 6S2P mean I should enter 12 series cells?

Enter six series groups. Parallel cells increase capacity and share current within each group while leaving the group voltage unchanged.

How do I convert a group’s measured resistance from ohms to mΩ?