3S 550 mAh micro quad XT30 and voltage sag
Screen a 3S 550 mAh micro quad pack at 12 A, including cell resistance, voltage drop and the XT30 reference.
Small pack capacity and higher cell resistance make sag noticeable even at a modest current. Compare the loaded cell voltage with your configured floor.
Example results
Check the highlighted inputs to calculate results.
- Estimated loaded pack voltage
- 11.36 V
- Pack voltage sag
- 0.642 V
- ESC headroom vs. rating
- 75 %
Voltage under full-throttle load
- Pack continuous rating
- 24.75 A
- Pack burst rating
- 35.75 A
- Current per ESC
- 3 A
- Average loaded cell voltage
- 3.786 V
- Total modeled resistance
- 53.5 mΩ
- Connector screening result
- XT30
Scenario inputs
- Rated pack capacity
- 550 mAh
- Cells or parallel groups in series
- 3 S
- Starting open-circuit voltage per group
- 4 V
- Continuous discharge rating
- 45 C
- Burst discharge rating
- 65 C
- Resistance per series group
- 15.5 mΩ
- Total lead and connector resistance
- 7 mΩ
- Full-throttle pack draw
- 12 A
- Number of ESC channels
- 4
- Continuous current per ESC channel
- 12 A
- Loaded voltage floor per group
- 3.5 V
Worked math
Equations use metric inputs unless a conventional unit is shown.
- Continuous and burst currents
0.55 Ah × 45C / 65C = 24.75 A continuous / 35.75 A burst - Pack and lead resistance
3 × 15.5 mΩ + 7 mΩ = 53.5 mΩ - Voltage under load
12 V − (12 A × 0.0535 Ω) = 11.358 V - ESC headroom
12 A ÷ 4 = 3 A/ESC · (12 − 3) ÷ 12 = 75% - Connector screen
12 A ≤ 15 A illustrative continuous screen for XT30
Model assumptions
Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.
The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.
ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.
Frequently asked questions
What current goes through the XT30 in this 3S micro preset?
The battery connector sees the total pack current, 12 A. The ESC estimate divides that current across four motor channels.
How much pack sag comes from the 7 mΩ lead estimate at 12 A?
Multiplying 12 A by 0.007 Ω gives 0.084 V of lead and connector drop in addition to cell sag.