Worked example

3S 550 mAh micro quad XT30 and voltage sag

Screen a 3S 550 mAh micro quad pack at 12 A, including cell resistance, voltage drop and the XT30 reference.

Small pack capacity and higher cell resistance make sag noticeable even at a modest current. Compare the loaded cell voltage with your configured floor.

Inputs

Battery & resistance

Enter effective resistance of a parallel group for an nS2P pack.

Load & ESC
View results

Example results

Estimated loaded pack voltage
11.36 V
Pack voltage sag
0.642 V
ESC headroom vs. rating
75 %

Voltage under full-throttle load

Voltage under full-throttle loadOpen circuit is 12 volts. The estimated loaded pack voltage is 11.358 volts. The reference cutoff is 10.5 volts. Open-circuit voltage12 VEstimated loaded voltage11.358 VVoltage sag · 0.642 VPack cutoff · 10.5 V
Gold marks the entered cell cutoff multiplied by the number of series cells.
Pack continuous rating
24.75 A
Pack burst rating
35.75 A
Current per ESC
3 A
Average loaded cell voltage
3.786 V
Total modeled resistance
53.5 mΩ
Connector screening result
XT30

Worked math

Equations use metric inputs unless a conventional unit is shown.

  1. Continuous and burst currents

    0.55 Ah × 45C / 65C = 24.75 A continuous / 35.75 A burst

  2. Pack and lead resistance

    3 × 15.5 mΩ + 7 mΩ = 53.5 mΩ

  3. Voltage under load

    12 V − (12 A × 0.0535 Ω) = 11.358 V

  4. ESC headroom

    12 A ÷ 4 = 3 A/ESC · (12 − 3) ÷ 12 = 75%

  5. Connector screen

    12 A ≤ 15 A illustrative continuous screen for XT30

Model assumptions

Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.

The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.

ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.

Frequently asked questions

What current goes through the XT30 in this 3S micro preset?

The battery connector sees the total pack current, 12 A. The ESC estimate divides that current across four motor channels.

How much pack sag comes from the 7 mΩ lead estimate at 12 A?

Multiplying 12 A by 0.007 Ω gives 0.084 V of lead and connector drop in addition to cell sag.