Worked example

4S 1500 mAh 75C pack sag and XT60 current screen

Calculate loaded 4S voltage with a 29 A draw and see how a 1500 mAh 75C pack compares with the connector and ESC screens.

The current falls just below the illustrative XT60 screen. Check the actual connector and leads for temperature rise at the intended duration.

Inputs

Battery & resistance

Enter effective resistance of a parallel group for an nS2P pack.

Load & ESC
View results

Example results

Estimated loaded pack voltage
15.34 V
Pack voltage sag
0.864 V
ESC headroom vs. rating
75.8 %

Voltage under full-throttle load

Voltage under full-throttle loadOpen circuit is 16.2 volts. The estimated loaded pack voltage is 15.336 volts. The reference cutoff is 13.6 volts. Open-circuit voltage16.2 VEstimated loaded voltage15.336 VVoltage sag · 0.864 VPack cutoff · 13.6 V
Gold marks the entered cell cutoff multiplied by the number of series cells.
Pack continuous rating
112.5 A
Pack burst rating
142.5 A
Current per ESC
7.25 A
Average loaded cell voltage
3.834 V
Total modeled resistance
29.8 mΩ
Connector screening result
XT60

Worked math

Equations use metric inputs unless a conventional unit is shown.

  1. Continuous and burst currents

    1.5 Ah × 75C / 95C = 112.5 A continuous / 142.5 A burst

  2. Pack and lead resistance

    4 × 6.4 mΩ + 4.2 mΩ = 29.8 mΩ

  3. Voltage under load

    16.2 V − (29 A × 0.0298 Ω) = 15.336 V

  4. ESC headroom

    29 A ÷ 4 = 7.25 A/ESC · (30 − 7.25) ÷ 30 = 75.833%

  5. Connector screen

    29 A ≤ 30 A illustrative continuous screen for XT60

Model assumptions

Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.

The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.

ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.

Frequently asked questions

Why include 4.2 mΩ of wiring along with 4S cell resistance?

Both the leads and connector contribute series resistance at pack current. Accounting for both gives a more complete voltage-drop estimate.

What does the XT60 screen mean at a 29 A load?

The current falls under the tool’s illustrative 30 A threshold. Verify the connector variant, contacts, lead gauge and test temperature for the installation.