4S 1500 mAh 75C pack sag and XT60 current screen
Calculate loaded 4S voltage with a 29 A draw and see how a 1500 mAh 75C pack compares with the connector and ESC screens.
The current falls just below the illustrative XT60 screen. Check the actual connector and leads for temperature rise at the intended duration.
Example results
Check the highlighted inputs to calculate results.
- Estimated loaded pack voltage
- 15.34 V
- Pack voltage sag
- 0.864 V
- ESC headroom vs. rating
- 75.8 %
Voltage under full-throttle load
- Pack continuous rating
- 112.5 A
- Pack burst rating
- 142.5 A
- Current per ESC
- 7.25 A
- Average loaded cell voltage
- 3.834 V
- Total modeled resistance
- 29.8 mΩ
- Connector screening result
- XT60
Scenario inputs
- Rated pack capacity
- 1,500 mAh
- Cells or parallel groups in series
- 4 S
- Starting open-circuit voltage per group
- 4.05 V
- Continuous discharge rating
- 75 C
- Burst discharge rating
- 95 C
- Resistance per series group
- 6.4 mΩ
- Total lead and connector resistance
- 4.2 mΩ
- Full-throttle pack draw
- 29 A
- Number of ESC channels
- 4
- Continuous current per ESC channel
- 30 A
- Loaded voltage floor per group
- 3.4 V
Worked math
Equations use metric inputs unless a conventional unit is shown.
- Continuous and burst currents
1.5 Ah × 75C / 95C = 112.5 A continuous / 142.5 A burst - Pack and lead resistance
4 × 6.4 mΩ + 4.2 mΩ = 29.8 mΩ - Voltage under load
16.2 V − (29 A × 0.0298 Ω) = 15.336 V - ESC headroom
29 A ÷ 4 = 7.25 A/ESC · (30 − 7.25) ÷ 30 = 75.833% - Connector screen
29 A ≤ 30 A illustrative continuous screen for XT60
Model assumptions
Multiply nameplate amp-hours by the entered C-ratings. The ratings apply to the complete pack. Burst duration and usable current depend on manufacturer specifications and test conditions.
The sag model multiplies total modeled resistance by pack current and subtracts from open-circuit pack voltage. Resistance varies with temperature, charge, condition and pulse duration.
ESC headroom is unused continuous rating divided by the rating, with equal current per channel assumed. The XT30, XT60 and XT90 screening limits are 15 A, 30 A and 45 A. Check the actual connector variant, leads and thermal limits against manufacturer data.
Frequently asked questions
Why include 4.2 mΩ of wiring along with 4S cell resistance?
Both the leads and connector contribute series resistance at pack current. Accounting for both gives a more complete voltage-drop estimate.
What does the XT60 screen mean at a 29 A load?
The current falls under the tool’s illustrative 30 A threshold. Verify the connector variant, contacts, lead gauge and test temperature for the installation.