Worked example

Cylinder flow time 3.04 h

  1. Reserve 15% of the 125 ft³ rated free volume, leaving 106.25 ft³ available in this estimate.
  2. Divide by 35 ft³ per hour for continuous flow time. The weld variables in the worksheet also show consumption for a single job.

Before using this result. Check your gas supplier’s reference conditions and regulator calibration. Include purge and leaks when comparing against real cylinder use.

Formulas and assumptions

Arc energy = 60 VI / (1,000 v)
With v in mm/min the result is kJ/mm. Use in/min for kJ/in. Net heat input multiplies arc energy by the entered arc efficiency.
Fillet area = ab/2
A flat-faced 90° fillet is a right triangle. The throat normal to the face is ab/√(a² + b²).
Filler mass = area × run length × runs × density / ηd
Divide the ideal deposited mass by the fractional deposition efficiency. Convert length and density to consistent units.
Gas volume = flow × arc-on time
Runtime uses cylinder free volume after reserve. Divide by the selected flow at matching reference conditions.

Engineering references

Frequently asked questions

Does three hours of gas flow mean three hours of working time?

The estimate is clock time with the valve flowing. Setup and stops typically increase total shop time, while purge and leaks reduce available arc time.

How do I account for a partially used 125 ft³ bottle?

Enter the estimated remaining free gas capacity supplied by your gauge or supplier method, then apply any reserve to that remaining amount.