Worked example
Wire or rod consumed 1.309 lb
- Use 0.03125 in² for the ideal fillet area and 96 in for total travel. That gives a deposited volume of 3.0 in³.
- Convert volume to carbon-steel mass and divide by 0.65 to account for the entered stub, coating and process losses. The stick process uses no separate shielding-gas supply in this model.
Before using this result. Verify the low-hydrogen electrode procedure, handling, welding position and measured deposition loss for the job.
Formulas and assumptions
- Arc energy = 60 VI / (1,000 v)
- With v in mm/min the result is kJ/mm. Use in/min for kJ/in. Net heat input multiplies arc energy by the entered arc efficiency.
- Fillet area = ab/2
- A flat-faced 90° fillet is a right triangle. The throat normal to the face is ab/√(a² + b²).
- Filler mass = area × run length × runs × density / ηd
- Divide the ideal deposited mass by the fractional deposition efficiency. Convert length and density to consistent units.
- Gas volume = flow × arc-on time
- Runtime uses cylinder free volume after reserve. Divide by the selected flow at matching reference conditions.
Engineering references
Frequently asked questions
Why is the shielding gas section absent for E7018?
The coated electrode produces its own gas and slag shielding. The stick worksheet estimates rod consumption without an external cylinder.
What if I discard much longer E7018 stubs?
A longer unused stub lowers the share of purchased material deposited. Enter a lower efficiency based on your shop’s measured loss.