Worked example

Net heat input 0.2592 kJ/mm

  1. Multiply 12 V by 90 A for 1,080 W. Multiply by 60 and divide by 1,000 × 150 mm/min to calculate arc energy per millimeter.
  2. Apply the assumed TIG thermal efficiency of 60% to that arc energy. Use the 3 × 3 mm leg dimensions separately for the filler estimate.

Before using this result. Confirm the procedure’s required heat-input convention. For AC or pulsed welding, use the approved energy measurement instead of multiplying averaged display readings.

Formulas and assumptions

Arc energy = 60 VI / (1,000 v)
With v in mm/min the result is kJ/mm. Use in/min for kJ/in. Net heat input multiplies arc energy by the entered arc efficiency.
Fillet area = ab/2
A flat-faced 90° fillet is a right triangle. The throat normal to the face is ab/√(a² + b²).
Filler mass = area × run length × runs × density / ηd
Divide the ideal deposited mass by the fractional deposition efficiency. Convert length and density to consistent units.
Gas volume = flow × arc-on time
Runtime uses cylinder free volume after reserve. Divide by the selected flow at matching reference conditions.

Engineering references

Frequently asked questions

Does a 60% TIG arc efficiency mean 40% of the 308L rod is lost?

Arc efficiency describes energy transferred to the workpiece. Rod added to the joint uses its own deposition efficiency input.

Where do I enter argon purge flow on this TIG case?

Budget purge separately using backing gas flow and elapsed purge time. The worksheet counts torch gas during the arc.