Seasonal Water for a 75-Acre Furrow Field
Use 60% planning efficiency to estimate gross seasonal volume from 16 net inches across a 75-acre furrow field.
Planning estimate
Measured flow is below the peak ET target for the available pumping window.
- Pump runtime for this event
- 149.75 h
- Net water reaching crop
- 3,665,828.6 US gal
- Gross water to pump
- 6,109,714.4 US gal
- Gross application depth
- 3 in
- Estimated application losses
- 2,443,885.7 US gal
- Flow per area for peak ET
- 10.18 gpm/ac
- Total flow needed for peak ET
- 763.7 US gpm
- Pumping time per peak day
- 22.46 h/day
- Seasonal gross volume
- 166.667 ac-ft
Field note
Furrow efficiency depends on soil, run length, advance and tailwater recovery. Use measured or locally estimated efficiency and track tailwater separately if required.
Questions from the field
What is the difference between net and gross seasonal depth?
Net depth is the water you intend to deliver to the crop root zone. Gross depth includes estimated delivery and application losses.
Does the worksheet credit reused tailwater automatically?
No reuse credit is built into the equations. Use an efficiency and measured delivery boundary that consistently represent your system.