GasCompressLab

Weymouth · Panhandle B · RP 14E

Gas pipeline pressure & velocity

Estimate outlet pressure with Darcy, Weymouth, or Panhandle B and compare inlet and outlet velocities to an API RP 14E screen.

Operating readout

Edit inputs ↓
Outlet press.
4,913.72kPa(a)
Pressure drop
286.28kPa
Outlet velocity
2.63m/s
Erosion use
13.83%
Within velocity screening limitThe outlet is within the selected API RP 14E comparison value.
Gas line section and longitudinal pressure profileISOTHERMAL GAS LINEkPa(a)P₁ 5200P₂ 4910Δz 85 mLONGITUDINAL PRESSUREkPa(a)52004910028 kmOUTLET EROSION USE13.8%
The line follows the entered elevation change. The plot uses the pressure-squared model at each distance along the run.
Calculated details
Inlet gas velocity
2.49m/s
Inlet RP 14E comparison
18.49m/s
Outlet RP 14E comparison
19.02m/s
Inlet gas density
43.55kg/m³
Outlet gas density
41.15kg/m³
Elevation correction exponent
0.01396
Outlet isothermal Mach
0.0076
Mass flow used
19,739.49kg/h

Operating inputs

Pipeline duty
kPa(a)
Nm³/h
km
mm
m
Positive for an uphill run.
Gas and resistance
°C
%

Calculation basis

Solve the pressure-squared balance

With constant Z and temperature, use s = 2gΔz/(ZRₛT) and equivalent length L·expm1(s)/s. Solve for P₂ in the pressure-squared difference P₁² − eˢP₂². The Darcy mode uses the entered friction factor. Weymouth and Panhandle B use their published US-unit flow coefficients.

Compare velocity

Convert standard volumetric flow to mass, then divide by local density and flow area. The RP 14E comparison is C/√ρ in ft/s with density in lb/ft³. The outlet governs for a declining, isothermal pressure profile.

Worked examples