GasCompressLab

Fan similarity · Surge margin

Affinity laws & anti-surge margin

Scale compressor or fan flow, head and shaft power with speed, then estimate surge margin and minimum recycle flow.

Operating readout

Edit inputs ↓
Scaled flow
9,112.38m³/h
Shaft power
157.7kW
Surge margin
6.22%
Recycle flow
268.78m³/h
Surge margin warningRecycle is required to reach the selected minimum compressor flow.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 10500N₂ 9200rpm23500012000 m³/hFLOW / CONTROL LINE96%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
1,289.75m
Equivalent pressure rise
50.47kPa
Dimensionless specific speed
1.28517
Scaled surge point
6,001.9m³/h
Minimum stable flow at target margin
6,668.78m³/h
Demand plus required recycle
6,668.78m³/h
Turn-down, nominal / minimum
1.366×
Reference shaft power
246.79kW
Speed ratio N₂ / N₁
0.8762×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.