GasCompressLab

Weymouth · Panhandle B · RP 14E

Darcy short plant transfer line

A short dry-gas run is screened with an entered Darcy friction factor of 0.018.

What to check

The friction factor and efficiency determine the pressure-squared budget in this mode.

Operating readout

Edit inputs ↓
Outlet press.
1,413.86kPa(a)
Pressure drop
16.14kPa
Outlet velocity
3.22m/s
Erosion use
9.09%
Within velocity screening limitThe outlet is within the selected API RP 14E comparison value.
Gas line section and longitudinal pressure profileISOTHERMAL GAS LINEkPa(a)P₁ 1430P₂ 1410Δz 12 mLONGITUDINAL PRESSUREkPa(a)1430141001.45 kmOUTLET EROSION USE9.09%
The line follows the entered elevation change. The plot uses the pressure-squared model at each distance along the run.
Calculated details
Inlet gas velocity
3.19m/s
Inlet RP 14E comparison
35.25m/s
Outlet RP 14E comparison
35.45m/s
Inlet gas density
11.97kg/m³
Outlet gas density
11.84kg/m³
Elevation correction exponent
0.00197
Outlet isothermal Mach
0.0093
Mass flow used
1,553.96kg/h

Operating inputs

Pipeline duty
kPa(a)
Nm³/h
km
mm
m
Positive for an uphill run.
Gas and resistance
°C
%

Calculation basis

Solve the pressure-squared balance

With constant Z and temperature, use s = 2gΔz/(ZRₛT) and equivalent length L·expm1(s)/s. Solve for P₂ in the pressure-squared difference P₁² − eˢP₂². The Darcy mode uses the entered friction factor. Weymouth and Panhandle B use their published US-unit flow coefficients.

Compare velocity

Convert standard volumetric flow to mass, then divide by local density and flow area. The RP 14E comparison is C/√ρ in ft/s with density in lb/ft³. The outlet governs for a declining, isothermal pressure profile.