GasCompressLab

Weymouth · Panhandle B · RP 14E

Downhill export segment

A descending fuel gas line has enough friction loss to retain a lower outlet pressure.

What to check

Negative elevation partly offsets friction. Review the elevation exponent and outlet pressure together.

Operating readout

Edit inputs ↓
Outlet press.
1,986.53kPa(a)
Pressure drop
313.47kPa
Outlet velocity
4.44m/s
Erosion use
14.62%
Within velocity screening limitThe outlet is within the selected API RP 14E comparison value.
Gas line section and longitudinal pressure profileISOTHERMAL GAS LINEkPa(a)P₁ 2300P₂ 1990Δz -170 mLONGITUDINAL PRESSUREkPa(a)23001990018 kmOUTLET EROSION USE14.6%
The line follows the entered elevation change. The plot uses the pressure-squared model at each distance along the run.
Calculated details
Inlet gas velocity
3.84m/s
Inlet RP 14E comparison
28.25m/s
Outlet RP 14E comparison
30.4m/s
Inlet gas density
18.65kg/m³
Outlet gas density
16.1kg/m³
Elevation correction exponent
-0.02703
Outlet isothermal Mach
0.0127
Mass flow used
5,375.86kg/h

Operating inputs

Pipeline duty
kPa(a)
Nm³/h
km
mm
m
Positive for an uphill run.
Gas and resistance
°C
%

Calculation basis

Solve the pressure-squared balance

With constant Z and temperature, use s = 2gΔz/(ZRₛT) and equivalent length L·expm1(s)/s. Solve for P₂ in the pressure-squared difference P₁² − eˢP₂². The Darcy mode uses the entered friction factor. Weymouth and Panhandle B use their published US-unit flow coefficients.

Compare velocity

Convert standard volumetric flow to mass, then divide by local density and flow area. The RP 14E comparison is C/√ρ in ft/s with density in lb/ft³. The outlet governs for a declining, isothermal pressure profile.