GasCompressLab

Weymouth · Panhandle B · RP 14E

High-velocity plant header

A short section with a high volumetric loading illustrates when RP 14E comparison can be exceeded.

What to check

Velocity utilization changes with density even when the pressure profile appears nearly flat.

Operating readout

Edit inputs ↓
Outlet press.
1,346.45kPa(a)
Pressure drop
103.55kPa
Outlet velocity
40.21m/s
Erosion use
106.66%
Erosional screen exceededOutlet velocity exceeds the selected API RP 14E comparison value.
Gas line section and longitudinal pressure profileISOTHERMAL GAS LINEkPa(a)P₁ 1450P₂ 1350Δz 3 mLONGITUDINAL PRESSUREkPa(a)1450135000.06 kmOUTLET EROSION USE107%
The line follows the entered elevation change. The plot uses the pressure-squared model at each distance along the run.
Calculated details
Inlet gas velocity
37.34m/s
Inlet RP 14E comparison
36.33m/s
Outlet RP 14E comparison
37.7m/s
Inlet gas density
11.28kg/m³
Outlet gas density
10.47kg/m³
Elevation correction exponent
0.00046
Outlet isothermal Mach
0.1121
Mass flow used
8,399.78kg/h

Operating inputs

Pipeline duty
kPa(a)
Nm³/h
km
mm
m
Positive for an uphill run.
Gas and resistance
°C
%

Calculation basis

Solve the pressure-squared balance

With constant Z and temperature, use s = 2gΔz/(ZRₛT) and equivalent length L·expm1(s)/s. Solve for P₂ in the pressure-squared difference P₁² − eˢP₂². The Darcy mode uses the entered friction factor. Weymouth and Panhandle B use their published US-unit flow coefficients.

Compare velocity

Convert standard volumetric flow to mass, then divide by local density and flow area. The RP 14E comparison is C/√ρ in ft/s with density in lb/ft³. The outlet governs for a declining, isothermal pressure profile.

Related worked examples