GasCompressLab

Weymouth · Panhandle B · RP 14E

Panhandle B regional transmission

A long transmission segment uses Panhandle B at 182,000 Nm³/h and a 610 mm ID.

What to check

Try Weymouth to see model sensitivity while keeping the same base, geometry and gas properties.

Operating readout

Edit inputs ↓
Outlet press.
7,353.67kPa(a)
Pressure drop
246.33kPa
Outlet velocity
2.28m/s
Erosion use
14.34%
Within velocity screening limitThe outlet is within the selected API RP 14E comparison value.
Gas line section and longitudinal pressure profileISOTHERMAL GAS LINEkPa(a)P₁ 7600P₂ 7350Δz 60 mLONGITUDINAL PRESSUREkPa(a)76007350092 kmOUTLET EROSION USE14.3%
The line follows the entered elevation change. The plot uses the pressure-squared model at each distance along the run.
Calculated details
Inlet gas velocity
2.21m/s
Inlet RP 14E comparison
15.65m/s
Outlet RP 14E comparison
15.91m/s
Inlet gas density
60.75kg/m³
Outlet gas density
58.78kg/m³
Elevation correction exponent
0.00941
Outlet isothermal Mach
0.0065
Mass flow used
141,116.37kg/h

Operating inputs

Pipeline duty
kPa(a)
Nm³/h
km
mm
m
Positive for an uphill run.
Gas and resistance
°C
%

Calculation basis

Solve the pressure-squared balance

With constant Z and temperature, use s = 2gΔz/(ZRₛT) and equivalent length L·expm1(s)/s. Solve for P₂ in the pressure-squared difference P₁² − eˢP₂². The Darcy mode uses the entered friction factor. Weymouth and Panhandle B use their published US-unit flow coefficients.

Compare velocity

Convert standard volumetric flow to mass, then divide by local density and flow area. The RP 14E comparison is C/√ρ in ft/s with density in lb/ft³. The outlet governs for a declining, isothermal pressure profile.

Related worked examples